SAFETY.
·
Panels of protection of the inner parts fastened with screws.
·
Water level sensor.
FOR THE NETWORK CONNECTED VERSION
WARNING
Configuration with connection to the water mains:
If you the boiler empties for reasons due to the interruption of water supply
network, the resistance could burn, since there is no sensor that can prevent
it.
FOR TANK CONFIGURATION
When the water reaches the minimum level (1.5 cm from the bottom of the basin), automatically
all machine functions are disabled, only the level lamp remains on, indicating lack of water. Turn
off the machine by placing the main switch on “OFF” and fill the water tank as described in
the relevant paragraph.
SAFETY THERMOSTAT
·
It turns on when the temperature in the boiler reaches 150°C by disconnecting the voltage
to the resistance in order to prevent the burn.