background image

Safety Guide

4

Warranty and technical

Warranty

Technical

If a Vax machine is used in the way it is intended and it breaks down within the 

guarantee period, it’s our responsibility to repair or replace it. 
Here’s what isn’t covered:

• Functional parts, tools and accessories after 12 months that may suffer 

premature failure due to every day wear and tear.

• Consumables after 3 months such as belts, filters, brushbars, fuses etc. 

• Accidental damage.

• Cosmetic damage that does not affect the functioning of the product.

• Damage as a result of use not in accordance with the user guide.

• Damage caused by not carrying out regular maintenance.

• Damage to the cable.

• Blockages; please refer to the user guide.

• Poor product performance caused by:

 

- Negligent use, misuse or careless operation of the machine.

 

- Failure to clean or maintain the product in accordance with the user guide.

 

- Use of the machine which is not in accordance with the user guide.

 

- Use of a Vax product for anything other than normal domestic household 

purposes in the country in which it was purchased.

 

- Use of parts, accessories and consumables, which are not genuine Vax 

components.

 

- Faulty installation or repairs - unless carried out by a qualified electrician or 

engineer.

Statement of Compliance: Manufacturer/EU importer: Vax Limited, hereby on 

our own responsibility, declare that the 

VAX

 

Air

TM

 Lift 2 

series is manufactured 

in compliance with the following Legislation: Safety: 2014/35/EU Low Voltage 

Directives/Electrical Equipment (Safety) Regulations 2016.

EMC: 2014/30/EU Electromagnetic Compatibility Directive/Electromagnetic 

Compatibility Regulations 2016.

Waste electrical products should not be disposed of with household  

waste. Please recycle where facilities exist. Check with your Local  

Authority or retailer for recycling advice.

VAX is a trade mark of Techtronic Cordless GP.

© 2021 Techtronic Cordless GP. All rights reserved.

Vax Ltd, Artillery House, Heritage Way, Droitwich, WR9 8YB, UK.

Summary of Contents for Air Lift 2

Page 1: ...CDUP PLXS CDUP PLXP User Guide VAX AirLift 2 Corded Vacuum...

Page 2: ...up hot coals cigarette butts matches or smoking hot burning items or use in an area where there may be harmful fluids chlorine bleach and ammonia drain cleaner Don t attempt to remove blockages with s...

Page 3: ...ne before disconnecting or connecting the hose and accessories Turn off all controls on the machine before connecting or disconnecting the plug from the mains socket Always keep the power cord away fr...

Page 4: ...Handle 2 Extension wand 3 Power ON OFF button 4 Lift out release button 5 Dirt container release button 6 Brush ON OFF button 7 Carry handle 8 Dirt container lid release clip 9 Separator 10 Hose 11 D...

Page 5: ...3 Quick Start Scan here For help and support with your new product or visit us online support vax co uk Still need to get in touch Our UK based Customer Care Team are here to support you For help wit...

Page 6: ...he machine which is not in accordance with the user guide Use of a Vax product for anything other than normal domestic household purposes in the country in which it was purchased Use of parts accessor...

Page 7: ...unplug the machine and remove and empty the dirt container Check the machine for blockages and clean the filters if required Allow the machine to cool for approximately 1 hour If you have washed the...

Page 8: ...at is not suitable for use with a rotating brushbar Place a foot on the floorhead and pull the handle backwards to recline Clip the cord into the cord hook so that the cord does not get pulled caught...

Page 9: ...the lift out base onto the back panel and floorhead In a hinge like manner push the lift out backwards until it clicks into place Press the On Off button to switch the machine on Lift and remove the...

Page 10: ...e For easier cleaning detach the lift out for stair and above floor cleaning Hold the lift out by the carry handle at all times when detached and take extra care when positioning on the stairs Using t...

Page 11: ...Press the On Off button to switch the machine on Hold the carry handle and press the lift out release button LIFT OUT ON OFF Using the accessories with the lift out IMPORTANT Hold the lift out by the...

Page 12: ...e emptying the dirt container The motor is equipped with a thermal cut out If for any reason the machine should overheat the thermostat will automatically turn the machine off If this happens switch o...

Page 13: ...e any dirt and debris from the separator Refit the separator making sure that the semi circular tab on the separator fits into the groove on the dirt container Pull the pre motor filter tab and remove...

Page 14: ...r into the floorhead Align the arrow on the brushbar cover to the unlock symbol push firmly until the cover sits flush and turn to lock into place IMPORTANT If the brushes have been obstructed the mot...

Page 15: ...lockages and use a blunt object to remove the blockage Clear any dirt debris inside the brush housing Use a damp cloth to remove any dirt debris from the brushroll Allow the brushroll to fully dry bef...

Page 16: ...ainer release button located on the top of the carry handle pull to remove the dirt container Open the Turbo Tool by removing the 2 screws with a crosshead screwdriver DIRT CONTAINER Press the hose en...

Page 17: ...dirt container page 10 The separator may be blocked Check and clear any blockages See Cleaning the separator page 11 The filters may need cleaning or replacing See Cleaning the pre motor filter page 1...

Page 18: ...Vax Ltd Artillery House Heritage Way Droitwich WR9 8YB UK info vax co uk vax co uk For how to videos and warranty registration visit www vax co uk...

Reviews: