background image

OPERATING INSTRUCTIONS 2000 KS                                                                        V7.4/20-EN 

Page| 4 

 

It is essential to disconnect the spray gun from the compressed 
air connection. 

 

Only use original spare parts . 

 

 

The maximum working pressure must not be  exceeded (see 

point  1  "Technical  data").  The  working  pressure  must  be 
adjusted via a (filter) pressure reducer. 

 

Only use compressed air as energy source. 

 

The compressed air connection may only be made via a quick 
coupling. 

 

When working with the spray gun, wear the necessary protec-
tive clothing, safety goggles, work gloves, ear protection if nec-
essary and a respiratory mask. 

 

If there are leaks in the device or other operating faults, the 
device must be disconnected from the compressed air supply 
immediately and the cause of the fault must be eliminated. 

 

Open fire, sparks or smoking is prohibited. 

 

Beware of flammable materials. 

 

Stone chip and underbody protection remains as well as clean-
ing media must be disposed of in an environmentally friendly 
manner. 

 

The disposal of the compressed air device must be carried out 
according to the valid legal regulations. 

 

6.

 

Installation 

Screw in the supplied steel riser pipe hand-tight. Pierce the protective foil of 
the 1 litre can and dip the riser pipe into the spraying material. Screw the 1 litre 
can into the plastic threaded cap of the spray gun 

hand-tight

. Take care not to 

overtighten the thread! 
Connect the spray gun to the compressed air supply via the quick coupling. By 
pressing the trigger you put the spray gun into operation. 
 
The spray pattern can be influenced by the following factors:

 

 

Distance between spray nozzle and object 

 

Angle of the gun to the object 

 
7.

 

Maintenance and care 

After each use, disconnect the device from the compressed air supply and thor-
oughly  clean  it.  We  recommend  benzine  or  commercially  available  terpene-
based cleaners. 

Do not use aggressive cleaners! 

Following the maintenance in-

structions will ensure a long service life and trouble-free operation of this qual-
ity product. 

 

Summary of Contents for 2000 KS

Page 1: ...OPERATING INSTRUCTIONS 2000 KS V7 4 20 EN Page 1 Spray gun 2000 KS Art no 20001 20002 20004 ...

Page 2: ...e always keep this operating manual with the spray gun General notices This spray gun was developed for specific applications We explicitly point out that this spray gun must not be modified and or used in a way that does not correspond to its intended use Content 1 Technical data 3 2 Extent of delivery 3 3 Intended use 3 4 Features 3 5 Safety instructions 3 6 Installation 4 7 Maintenance and care...

Page 3: ...ir stream is used which accelerates when the air nozzle flows through and thus generates negative pressure in the adjoining riser pipe The spray mass is thereby sucked in and sprayed out via the nozzle by the air flow 5 Safety instructions Protect yourself and the environment by taking appropriate precautions against the risk of accidents and observe the following instructions in your own interest...

Page 4: ...as clean ing media must be disposed of in an environmentally friendly manner The disposal of the compressed air device must be carried out according to the valid legal regulations 6 Installation Screw in the supplied steel riser pipe hand tight Pierce the protective foil of the 1 litre can and dip the riser pipe into the spraying material Screw the 1 litre can into the plastic threaded cap of the ...

Page 5: ... riser pipe or ventilation hole dirty Solution Clean parts Gun does not spray any material Possible cause Riser pipe plastic spray pipe clogged Solution Clean clogged parts Air escapes from the spray nozzle even though the trigger is in its initial position Possible cause Valve bolt is jammed Solution Pour oil onto the valve bolt and or into the compressed air intake Operate the trigger several ti...

Page 6: ... your sales representative is at your side or contact the following address Company Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach Germany Telephone 49 0 2774 80069 0 E Mail info vaupel gmbh de Internet www vaupel gmbh de Notice We reserve the right to make technical changes Illustrations may differ from the original We assume no liability for printing errors ...

Page 7: ...formity with the above EC Di rectives under the general responsibility of Company Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach The technical documentation is complete The following harmonised standard has been applied DIN EN ISO 12100 Sicherheit von Maschinen Allgemeine Gestaltungsleit sätze Risikobeurteilung und Risikominderung The operating manual belonging ...

Page 8: ...0 029 Lock washer 5 80158 Valve bolt 6 O ring 1 5 x 0 75 mm 7 Valve seal 8 60 3103 003 Spring for valve 9 60 4100 062 O ring 8 x 1 mm 10 30 1120 002 Locking screw 12 30 1422 008 Air nozzle 2 5 mm 17 40 4428 001 Plastic spray pipe 2900 KS 21 40 4112 010 Threaded cap 21 A Ventilation hole 22 30 1432 018 Fixing screw m 10 x 1 mm 23 60 3129 001 Riser pipe 253 mm 24 Connection thread ...

Reviews: