INSTALLATION CHECKLIST
A.
INSPECTION AND PREPARING THE HEATER
Do not cover T and P relief valve opening.
B.
LOCATION
Solid foundation and dry location.
Protect heater water lines from freezing.
Area free of flammable vapors.
Sufficient room to service heater.
C.
PROTECTION FROM WATER DAMAGE
Be sure to make provisions to protect area from water damage if a leak should
occur in the tank or any connected fittings.
D.
TEMPERATURE & PRESSURE RELIEF VALVE
WARNING:
Improper installation will present potential hazard to life and
property.
A T&P Relief Valve with an 8-inch stem should be used
Check to be sure that proper relief valve requirements are met.
Opening on top side.
Valve stem immersed in the water within the top 6” of the tank.
¾” discharge pipe—properly protected from freezing and restrictions.
No valve between tank and relief valve or in drain line.
Provision for hot water discharge from relief valve.
E.
WATER SUPPLY CONNECTIONS:
(SEE FIGURE I)
Do not over tighten brass threads.
Mark the water shut off for future reference.
Do not apply heat to combination inlet and drain.