3.9 To enter in parameters list Pr2 

To  reach  the  parameters  present  in  "Pr2"  (parameters 
accessible 

to 

the 

technicians), 

please 

contact 

,  which  will  deliver  you  the  secret  code 

making it possible to reach these parameters. 

 

4. ALARM SIGNALS 
Message 

Cause 

Output 

"P1" 

Thermostat probe 
failure 

Alarm output ON; Compressor 
output according to parameters 
“COn” and “COF” 

"P2" 

Evaporator probe 
failure 

Alarm output ON; Other outputs 
unchanged 

"HA" 

Maximum 
temperature alarm 

Alarm output ON; Other outputs 
unchanged 

"LA" 

Minimum 
temperature alarm 

Alarm output ON; Other outputs 
unchanged 

"EE" 

Data or memory 
failure 

Alarm output ON; Other outputs 
unchanged 

"dA" 

Door switch alarm 

Alarm output ON; Other outputs 
unchanged 

"EAL" 

External alarm 

Alarm output ON; Other outputs 
unchanged 

"BAL" 

Serious external 
alarm 

Alarm output ON; Other outputs 
OFF 

"PAL" 

Pressure switch 
alarm 

Alarm output ON; Other outputs 
OFF

 

 

The alarm message is displayed until the alarm condition is 
recovery. 
All the alarm messages  are  showed alternating with the room 
temperature except for the “P1” which is flashing. To reset the 
“EE”  alarm  and  restart  the  normal  functioning  press  any  key, 
the “

rSt

” message is displayed for about 3s. 

 

4.1 EE alarm 

The  instruments  are  provided  with  an  internal  check  for  the 
data  integrity.  Alarm  “EE”  flashes  when  a  failure  in  the 
memory  data  occurs.  In  such  cases  the  alarm  output  is 
enabled. 

4.2 Alarm recovery 

Probe alarms “

P1

” (probe1 faulty), “

P2

” ; they automatically 

stop 10s after the probe restarts normal operation. Check 
connections before replacing the probe. 
Temperature alarms “

HA

” and “

LA

” automatically stop as soon 

as the thermostat temperature returns to normal values or 
when the defrost starts. 

 

 
 
 
 
 
 
 
 

5. PARAMETERS PROGRAMS IN FACTORY 

 

Parameter  Name 

Value 

Set 

Set point 

Hy 

Differential 

AC 

Anti-short cycle delay 

rES 

Resolution (integer/decimal point) 

De 

tdF 

Defrost type 

rE 

dtE 

Defrost termination temperature 

IdF 

Interval between defrost cycles 

MdF 

(Maximum) length for defrost 

ALU 

MAXIMUM temperature alarm 

ALL 

Minimum temperature alarm 

ot 

Thermostat probe calibration 

P2P 

Evaporator probe presence 

Adr 

Address series (unused) 

P2r 

Access parameter list ( read only) 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for COOLBOX

Page 1: ...mostat page 4 Spare parts page page 6 Rue Charles Hermite Z I des Sables BP 59 54110 Dombasle sur Meurthe France tel 33 03 83 45 82 82 fax 33 03 83 45 82 93 e mail commercial vcs vauconsant com export vauconsant com COOLBOX Refrigerated cupboard with trolley Notice N CC103 mise à jour le 06 novembre 2006 ...

Page 2: ...out to supply power The thermostat is adjusted in the factory after testing When the desired temperature is obtained the power unit automatically turns off Press the key of the thermostat to turn off the regulation of the unit Adjusting the thermostat Refer to the manual for details Automatic defrosting This function is programmed in the thermostat Adjusted in the factory the defrosting engages ev...

Page 3: ...pillary Rt Modular timer Cd Condensor Sn Level probe Dh Drier St Atmosphere temperature probe E Evaporator T Thermostat Kb Self evaporating tray relay Tb Safety thermostat for self evaporating tray Im Engine of ascent and descent of the curtain Tm Transformer P Raising pomp V Ventilator Q Fuse holder Vc Condensor fan ...

Page 4: ...rd is locked At this point it is only possible the viewing of the set point or the MAX or Min temperature stored and to switch ON and OFF the light the auxilary output and the instrument HOW TO UNLOCK THE KEYBOARD Keep the and the keys pressed together for more than 3 s The POn message will be displayed and the keyboard is unlocked 3 2 Meaning of the LED Each LED function is described in the follo...

Page 5: ...howed alternating with the room temperature except for the P1 which is flashing To reset the EE alarm and restart the normal functioning press any key the rSt message is displayed for about 3s 4 1 EE alarm The instruments are provided with an internal check for the data integrity Alarm EE flashes when a failure in the memory data occurs In such cases the alarm output is enabled 4 2 Alarm recovery ...

Page 6: ...essories 09 3098 Motorized curtain Electric equipment 06 0038 Self evaporating tray heating element 06 3500 Ventilator 12 0270 Thermostat 12 0500 Praising pomp Refrigerating equipment 12 2480 Evaporator 12 2806 Group condensation CAJ 4517 ZH ...

Reviews: