INSTRUCTIONS OF USE AND MAINTENANCE 

 

GENERAL POINT

 

 

Refrigerating components 

Refrigeration by a ventilated evaporator located in the top of 

the cupboard. 

 

Self evaporating tray 

Evaporation by heating element, placed in a vat stainless, 

placed with the compressor. 

 

Controls 

High precision control by thermostat with digital display ( to 

refer to the note of the thermostat provided hereafter ). 

Started and stop of the regulation by pressure on the key 

 of the keyboard of the thermostat. 

 

Control devices placed on the panel of aeration of the 

compressor group of the display. 

 

Protection 

By main power fuse holder. 

 

INSTALLATION

 

 

Electric connection 

Before plugging in the unit, control imperatively the 

voltage rating : it should be the same voltage as 
indicated on the unit.

 

The electric power line providing the refrigerated unit with 

electricity should be protected by a differential circuit breaker 
located on the main electric distribution panel. 

 

HOW TO USE 

 

To put into service 

Powering up the unit two hours before usage. 

Press the key 

 of the thermostat 

When the thermostat is activated, the power unit starts 

running a minute later (safety timeout) to supply power. 

The thermostat is adjusted in the factory after testing. 
When the desired temperature is obtained, the power unit 

automatically turns off. 

Press the key 

 of the thermostat to turn off the regulation 

of the unit. 

 

Adjusting the thermostat 

Refer to the manual for details. 

 

Automatic defrosting 

This function is programmed in the thermostat/ 
Adjusted in the factory: the defrosting engages every hour 

throughout one ten maximum minute. 

To modify the adjustment, refer the manual of the 

thermostat.

 

 
 
 

 

Cleaning 

To be performed when the cupboard is shut down (the unit is 

turned off). 

Once a day, wash the top, the refrigerated well and the 

external sides of the cupboard. 

Use a sponge moistened with a soapy water or special 

cleaning products to clean the stainless steel. Rinse off with 
water. Dry preferably with lint-free cotton cloths. 

Do not use floor cleaning products or acids, even diluted, 

chlorinated or scouring products, which may cause corrosion to 
stainless steel. 

Do not use any abrasive products (steel wool, etc…). 
Do not clean the refrigerated unit by spraying with water, 

using a soap gun, or under high pressure jets. 

 

MAINTENANCE 

 

The installer should check all the electric connections during 

the initial start up of the unit (and then once a year). 

Clean the condenser every six months. 
Grease the condenser blower shaft once a year. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for COOLBOX

Page 1: ...mostat page 4 Spare parts page page 6 Rue Charles Hermite Z I des Sables BP 59 54110 Dombasle sur Meurthe France tel 33 03 83 45 82 82 fax 33 03 83 45 82 93 e mail commercial vcs vauconsant com export vauconsant com COOLBOX Refrigerated cupboard with trolley Notice N CC103 mise à jour le 06 novembre 2006 ...

Page 2: ...out to supply power The thermostat is adjusted in the factory after testing When the desired temperature is obtained the power unit automatically turns off Press the key of the thermostat to turn off the regulation of the unit Adjusting the thermostat Refer to the manual for details Automatic defrosting This function is programmed in the thermostat Adjusted in the factory the defrosting engages ev...

Page 3: ...pillary Rt Modular timer Cd Condensor Sn Level probe Dh Drier St Atmosphere temperature probe E Evaporator T Thermostat Kb Self evaporating tray relay Tb Safety thermostat for self evaporating tray Im Engine of ascent and descent of the curtain Tm Transformer P Raising pomp V Ventilator Q Fuse holder Vc Condensor fan ...

Page 4: ...rd is locked At this point it is only possible the viewing of the set point or the MAX or Min temperature stored and to switch ON and OFF the light the auxilary output and the instrument HOW TO UNLOCK THE KEYBOARD Keep the and the keys pressed together for more than 3 s The POn message will be displayed and the keyboard is unlocked 3 2 Meaning of the LED Each LED function is described in the follo...

Page 5: ...howed alternating with the room temperature except for the P1 which is flashing To reset the EE alarm and restart the normal functioning press any key the rSt message is displayed for about 3s 4 1 EE alarm The instruments are provided with an internal check for the data integrity Alarm EE flashes when a failure in the memory data occurs In such cases the alarm output is enabled 4 2 Alarm recovery ...

Page 6: ...essories 09 3098 Motorized curtain Electric equipment 06 0038 Self evaporating tray heating element 06 3500 Ventilator 12 0270 Thermostat 12 0500 Praising pomp Refrigerating equipment 12 2480 Evaporator 12 2806 Group condensation CAJ 4517 ZH ...

Reviews: