MANUAL OF THERMOSTAT XW60L 

 

  

 Please read this manual before using 

 

1.AVERTISSEMENT 

 

Warning:  disconnect  all  electrical  connections 
before any kind of maintenance. 

 

The instrument must not be opened.

 

 

In  case  of  failure  or  faulty  operation  send  the  instrument 
back  to  the  distributor  or  to 

  with  a 

detailed description of the fault. 

 

2.DESCRIPTION 

Model 

XW60L

  is  microprocessor  based  controllers  suitable 

for  applications  on  medium  or  low  temperature  refrigerating 
units.  They  are  provided  with  4  relay  outputs  to  control 
compressor,  defrost,  fans  for  the  evaporator  and  the  lights. 
They  are  also  provided  with  2  NTC  probe  inputs,  for 
temperature  control,  the  second  for  end  defrost  temperature 
control. 

The regulation is performed according to the temperature 

measured by the thermostat probe with a positive differential 
from the set point: if the temperature increases and reaches 
set point plus differential the compressor is started and then 
turned off when the temperature reaches the set point value 
again. 

 

3.KEYBOARD 

 

 

 

 

To  display  and  modify  target  set  point;  in 
programming  mode  it  selects  a  parameter  or  confirm 
an operation. 
By  holding  it  pressed  for  3s  when  max  or  min 
temperature is displayed it will be erased. 

 

To  see  the  max.  stored  temperature;  in  programming 
mode it browses the parameter codes or increases the 
displayed  value.  By  holding  it  pressed  for  3s  the  fast 
freezing cycle is started. 

 

To  see  the  min  stored  temperature;  in  programming 
mode it browses the parameter codes or decreases the 
displayed value. 

 

By holding it pressed for 3s the defrost is started. 

 

Switch ON and OFF the light of the cold-room. 

 

Switch ON and OFF the instrument. 

 

KEY COMBINATIONS 

 

 

 

To lock and unlock the keyboard. 

 

 

To enter the programming mode. 

 

 

To it the programming mode. 

 
3.1 To lock and unlock the keyboard 

 

HOW TO LOCK THE KEYBOARD 

 

Keep  the 

  and  the 

  keys  together  for  more 

than  3  s.  The  "POF"  message  will  be  displayed  and 
the  keyboard  is  locked.  At  this  point  it  is  only 
possible  the  viewing  of  the  set  point  or  the  MAX  or 
Min  temperature  stored  and  to  switch  ON  and  OFF 
the light, the auxilary output and the instrument. 

 

HOW TO UNLOCK THE KEYBOARD 

 

Keep the 

 and the 

 keys pressed together for 

more than 3 s. The "POn" message will be displayed 
and the keyboard is unlocked. 

 

3.2 Meaning of the LED 

Each LED function is described in the following table : 

 

LED 

MODE 

FONCTION 

 

ON 

The compressor is running 

 

Flashing 

Programmation phase ( flashing with 

Anti-short cycle delay enabled 

 

ON 

The fan is running. 

 

Flashing  Programmation phase ( flashing with 

 

ON 

The defrost is enabled. 

 

Flashing  Drip time in progress 

 

ON 

The fast freezing cycle is enable 

 

ON 

Alarm signal 
In “Pr2” indicates that the parameter is also 
present in “Pr1 

 

ON 

The light is on 

 

3.3 How to see the min temperature 

 

Press and release the 

n

 key. 

The  “Lo”  message  will  be  displayed  followed  by  the 
minimum temperature recorded. 
By  pressing  the 

n

  key  or  waiting  for  5s  the  normal 

display will be restored. 

 

3.4 How to see the max temperature 

 

Press and release the 

o

 key. 

The  “Hi”  message  will  be  displayed  followed  by  the 
maximum  temperature recorded. 
By  pressing  the 

o

  key  or  waiting  for  5s  the  normal 

display will be restored. 

 

3.5 How to reset the max and min temperature recorded 

To  reset  the  stored  temperature,  when  max  or  min 
temperature is displayed, press SET key until “rST” label starts 
blinking. 

N.B.  :  After  the  installation  RESET  the  temperature 
stored . 

 

3.6 How to see and modify the set point 

 

Push  and  immediately  release  the 

SET 

key:  the 

display will show the Set point value. 
The SET LED start blinking. 

To change the Set value push the 

 

or 

 arrows 

within 10s. 
To  memorise  the  new  set  point  value  push  the 

SET

 

key again or wait 10s. 

 

3.7 To start a manual defrost 

 

Push  the 

DEF 

key  for  more  than  2  seconds  and  a 

manual defrost will start. 

 

3.8 To enter in parameters list Pr1 

To enter the parameter list “Pr1” (user accessible parameters) 
operate as follows: 

 

Enter  the  Programming  mode  by  pressing  the 
Set and DOWN key for few seconds (

 and 

 

start blinking). 
The  instrument  will  show  the  first  parameter 
present in “Pr1”. 

Summary of Contents for COOLBOX

Page 1: ...mostat page 4 Spare parts page page 6 Rue Charles Hermite Z I des Sables BP 59 54110 Dombasle sur Meurthe France tel 33 03 83 45 82 82 fax 33 03 83 45 82 93 e mail commercial vcs vauconsant com export vauconsant com COOLBOX Refrigerated cupboard with trolley Notice N CC103 mise à jour le 06 novembre 2006 ...

Page 2: ...out to supply power The thermostat is adjusted in the factory after testing When the desired temperature is obtained the power unit automatically turns off Press the key of the thermostat to turn off the regulation of the unit Adjusting the thermostat Refer to the manual for details Automatic defrosting This function is programmed in the thermostat Adjusted in the factory the defrosting engages ev...

Page 3: ...pillary Rt Modular timer Cd Condensor Sn Level probe Dh Drier St Atmosphere temperature probe E Evaporator T Thermostat Kb Self evaporating tray relay Tb Safety thermostat for self evaporating tray Im Engine of ascent and descent of the curtain Tm Transformer P Raising pomp V Ventilator Q Fuse holder Vc Condensor fan ...

Page 4: ...rd is locked At this point it is only possible the viewing of the set point or the MAX or Min temperature stored and to switch ON and OFF the light the auxilary output and the instrument HOW TO UNLOCK THE KEYBOARD Keep the and the keys pressed together for more than 3 s The POn message will be displayed and the keyboard is unlocked 3 2 Meaning of the LED Each LED function is described in the follo...

Page 5: ...howed alternating with the room temperature except for the P1 which is flashing To reset the EE alarm and restart the normal functioning press any key the rSt message is displayed for about 3s 4 1 EE alarm The instruments are provided with an internal check for the data integrity Alarm EE flashes when a failure in the memory data occurs In such cases the alarm output is enabled 4 2 Alarm recovery ...

Page 6: ...essories 09 3098 Motorized curtain Electric equipment 06 0038 Self evaporating tray heating element 06 3500 Ventilator 12 0270 Thermostat 12 0500 Praising pomp Refrigerating equipment 12 2480 Evaporator 12 2806 Group condensation CAJ 4517 ZH ...

Reviews: