![VAT 653 Series Installation, Operating, & Maintenance Instructions Download Page 11](http://html1.mh-extra.com/html/vat/653-series/653-series_installation-operating-and-maintenance-instructions_4123560011.webp)
Series 65
DESCRIPTION OF PRODUCT
963283EA
Edition 2019-05-03
11/129
Description
- Seals
Viton
®
(standard). Other materials available.
Seal materials are declared on dimensional drawing of specific valve
ordering number.
DN 100
4"
(65340 - ....)
DN 160
6"
(65344 - ....)
DN 200
8"
(65346 - ....)
DN 250
10"
(65348 - ....)
Max. differential pressure on plate during isolation
1200 mbar in
either direction
1200 mbar in
either direction
1200 mbar in
either direction
1200 mbar in
either direction
Max. differential pressure on plate
during opening and throttling
30 mbar
10 mbar
5 mbar
5 mbar
Min. controllable conductance
(N
2
molecular flow)
Typ. 2 l/s
Typ. 4 l/s
Typ. 7 l/s
Typ. 10 l/s
Dimensions
Refer to dimensional drawing of specific valve ordering number
(available on request)