![VAT 616 Series Installation, Operating, & Maintenance Instructions Download Page 33](http://html1.mh-extra.com/html/vat/616-series/616-series_installation-operating-and-maintenance-instructions_4088275033.webp)
Series 616
MAINTENANCE
893179ED.DOCX
Edition 2020-01-22
33/56
7.2.1
Replacement of plate o-ring
7.2.1.1
Required tools
•
Allen Wrench 3mm
•
O-ring removal tool
(see chapter Accessories)
•
Vacuum grease (see chapter spare parts)
•
Cleanroom wipes
Description
Required tool
1. Vent vacuum system on both sides of the valve.
2. Move the plate to position 30% open.
3. Disconnect electrical POWER connector at valve and remove valve from
vacuum system.
Attention!
Electrical power is needed for plate adjustment in step 19.
Take care to the sealing surface!
4. Unfasten and remove the 2 fastening
screws
Allen Wrench
3mm
5. Push the plate a little down
6. Remove the plate on the other side of
shaft