Description
Required tool
11. Clean the valve body and
shaft.
12. Place the plate on the shaft.
13. Tighten plate screws to
block.
14. Loosen the plate screws a
quarter turn counter
clockwise.
Fact: Plate is now movable on
shaft and ready to sliding into
valve seat. Proceed with step 15.
Note: Take care to sealing
surface inside the valve body!
Cleanroom wipes soaked
with isopropyl alcohol
Allen Wrench
4mm
15. Connect electrical POWER
connection at valve
Attention!
Valve
does
synchronize
automatically and moves to
close
position!
16. Disconnect electrical POWER
connection
Attention!
Keep fingers out of the valve during valve
movement!
Assembl
e
and adj
ust pl
a
te
17. Tighten the plate screws
with:
•
2 Nm (DN 63)
•
3.5 Nm (DN 80-100)
Allen torque wrench
4mm
In
s
ta
ll
valve
in
to
syste
m
18. Reinstall valve into vacuum
system according to chapter
«Installation» of valve
manual