Procedure 1
Description
Required tool
Re
m
o
v
e
v
a
lv
e
fro
m
s
y
s
te
m
1. Vent vacuum system on both sides of valve.
2. Move the plate to position 30% open.
3. Disconnect electrical POWER connector at valve and remove valve from
vacuum system.
4. Note: Take care not to damage the sealing surface.
Depending on flange screws
5. Loosen and remove the
plate screws
Allen Wrench
4mm
R
e
move pl
at
e
6. Remove plate from counter
side
Note: Take care to sealing
surface inside the valve
body!