Installation, Operating & 
Maintenance Instructions 

 

 

773485EA 

Edition 2014-11-03 

 

 

Low particle gate valve 

with double acting pneumatic actuator 

 

Series 150 
DN 63 – 160 mm (I. D. 2½" – 6") 

 
 
This manual is valid for the following product ordering numbers: 

150

    

..

    

-

    

....

    

-

    

.... 

 
 
 

 

Sample picture 
 
 

Summary of Contents for 150 Series

Page 1: ...ntenance Instructions 773485EA Edition 2014 11 03 Low particle gate valve with double acting pneumatic actuator Series 150 DN 63 160 mm I D 2 6 This manual is valid for the following product ordering...

Page 2: ...duplicated or distributed without written permission from VAT Offenders are liable to pay damages The original VAT firmware and updated state of the art versions of the VAT firmware are intended for u...

Page 3: ...4 2 1 Admissible forces and bending moments 11 4 3 Compressed air connection 12 4 4 Electrical connection 12 5 Operation 13 5 1 Normal operation 13 5 2 Operation under increased temperature 13 5 3 Be...

Page 4: ...Series 150 4 27 Edition 2014 11 03 773485EA 10 Disposal 26 11 Spare parts 27...

Page 5: ...number Order number 1 2 Use of product Use product for clean and dry vacuum applications only Other applications are only allowed with the written permission of VAT 1 3 Related documents Product data...

Page 6: ...ion Operating Maintenance Instructions are an integral part of a comprehensive documentation belonging to a complete technical system They must be stored together with the other documentation and acce...

Page 7: ...nqualified personnel Inappropriate handling may cause serious injury or property damage Only qualified personnel are allowed to carry out the described work 2 4 Safety labels Label Part No Location on...

Page 8: ...g surface 2 Valve body 3 Actuator 4 Position indicator 5 Solenoid valve Figure 3 1 Sample picture 3 2 Function The valve features the MONOVAT sealing technology and a compact double acting actuator 1...

Page 9: ...e quality of the supplied products visually If it does not meet your requirements please contact VAT immediately Store the original packaging material It may be useful if products must be returned to...

Page 10: ...tions may occur Use only screws recommended by VAT 1 Remove protective covers from body flanges 2 Clean sealing surfaces and seals of both flanges see 1 and 2 according to Figure 4 1 The valve seat si...

Page 11: ...function of the valve The stress has to be relieved by suitable means see Table 4 1 below The following forces or bending moments are admissible DN nom I D Axial tensile or com pressive force FA Bendi...

Page 12: ...nge see product data sheet 1 Connect compressed air according to the product data sheet and dimensional drawing 4 4 Electrical connection DANGER Electric shock Parts being under voltage will result in...

Page 13: ...NG Movable parts Human body parts may get jammed and severely injured Do not operate before product is installed completely into the vacuum system 5 1 Normal operation Valve is opened and closed pneum...

Page 14: ...vable parts Only valid for the ordering number 150 34 44 with solenoid valve In case of a power failure the valve can be actuated manually if compressed air is available Standard solenoid valve Press...

Page 15: ...Connect voltage 4 4 Electrical connection Leak at gate Vulcanized gate all right Replace valve gate 6 4 Replacement of gate and bonnet seal Gate damaged or contaminated Replace valve gate 6 4 Replace...

Page 16: ...disconnect electrical power supply WARNING Movable parts Human body parts may get jammed and severely injured Keep human body parts away from movable parts 6 1 Maintenance intervals Under clean opera...

Page 17: ...ption Tightening torque Nm 2 Bonnet screw 15 0 Item No Description Tightening torque Nm 6 Gate fixation screw 20 0 Table 6 1 6 3 Required tools Open end wrench Torque wrench according Table 6 1 Cleanr...

Page 18: ...ackets refer to Figure 6 3 on page 20 1 Vent chambers on either side to atmospheric pressure 2 Open valve 3 Disconnect compressed air supply 4 Disconnect electrical power supply 5 Remove all screws 2...

Page 19: ...to groove on one short side Distribute seal uniformly over long sides to opposite short side and press it fully into groove Align gate with bonnet flange of upper part of body 16 Apply compressed air...

Page 20: ...ews 2 with the appropriate torque specified in chapter 6 2 Tightening torque specifications 20 Connect electrical power supply 21 Connect compressed air supply 22 Close the valve 1 Lower valve body 2...

Page 21: ...pairs may only be carried out by the VAT service staff In exceptional cases the customer is allowed to carry out the repairs but only with the prior consent of VAT Please contact one of our service ce...

Page 22: ...rry out the described work WARNING Hazardous components Human body parts may get jammed and severely injured Before dismounting the product disconnect compressed air supply disconnect electrical power...

Page 23: ...uctions 8 2 Storage NOTICE Wrong storage Inappropriate temperatures and humidity may cause damage to the product Valve must be stored at relative humidity between 10 and 70 temperature between 10 C an...

Page 24: ...he valve to VAT NOTICE Inappropriate packaging Product may get damaged if inappropriate packaging material is used Always use the original packaging material and handle product with care When returnin...

Page 25: ...ith a protective foil 2 Pack valve appropriately by using the original packaging material VAT disclaims any liability for damages resulting from inappropriate packaging 9 2 Transport NOTICE Inappropri...

Page 26: ...DISPOSAL Series 150 26 27 Edition 2014 11 03 773485EA 10 Disposal WARNING Harmful substances Environmental pollution Discard products and parts according to the local regulations...

Page 27: ...be replaced by the customer and those that need to be replaced by the VAT service staff Table 11 1 only contains spare parts that may be replaced by the customer If you need any other spare parts plea...