MAINTENANCE
Series 140
32/43
Edition 14.07.2020
875067EA
7.8
Removing rotary drive
NOTICE
Contamination
Product may get contaminated.
Always wear cleanroom gloves when handling the product.
NOTICE
Inappropriate tools
Sealing surfaces may get damaged.
Do not use sharp-edged tools.
Proceed as follows to remove the rotary drive:
1. Vent chambers on either side to atmospheric pressure.
2. Check and make sure valve is closed.
3. Disconnect compressed air supply.
4. Disconnect electrical power supply.
5. Remove valve gate. See chapter «7.3 Removing valve gate».
6. Remove position indicator. See chapter «7.6 Removing position indicator».
Figure 7-11
1
Dowel pin
2
Gate lever
2
1