MAINTENANCE
Series 140
26/43
Edition 14.07.2020
875067EA
7.4
Replacing gate O-ring
NOTICE
Contamination
Product may get contaminated.
Always wear cleanroom gloves when handling the product.
NOTICE
Inappropriate tools
Sealing surfaces may get damaged.
Do not use sharp-edged tools.
Proceed as follows to replace the gate O-ring:
1. Remove valve gate. See chapter «7.3 Removing valve gate».
Figure 7-5
1
Gate O-ring
2
Valve gate
2. Use O-ring removal tool (see chapter «7.2 Required tools») to remove gate O-ring (1)
from groove.
Do not damage the sealing surface!
1
2