MAINTENANCE
Series 140
30/43
Edition 14.07.2020
875067EA
7.6
Removing position indicator
Proceed as follows to remove the position indicator:
1. Vent chambers on either side to atmospheric pressure.
2. Check and make sure valve is closed.
3. Disconnect compressed air supply.
4. Disconnect electrical power supply.
Figure 7-9
1
Slotted screws
2
Position indicator
5. Loosen and remove four slotted screws (1) using a slotted screwdriver.
6. Remove position indicator (2).
1
2