background image

Maintenance

 

Electrical 

 

Electrical connections will loosen in time from heating and cooling. Every three (3) months the 

power should be turned 

off

 at the external disconnect, or unplugged, and all the points of connection should be inspected and tightened.

 

 

Lint Buildup 

 

As with your clothes dryer at home lint will build up where ever air is flowing over garments. 

 

 

 

Every six months

 

 

 

 

-

The top cover should be removed to clean around the heater and any other visible debris buildup. 

 

 

 

-

The side covering the blower box should be removed, and all lint be removed from around the exhaust blower.

 

 

-

The optional exhaust blower, located on the rear of the machine, should be cleaned every 

2

-

3 months

. To open the 

back panel of the exhaust blower, remove the (7) black #8 machine screws for access to the blower.

 

 

 

Motor &

 

Chains can loosen in time and should be inspected, adjusted, and lubricated when necessary. The motor chain is locat-

ed in the rear of the conveyor behind the Chain Guard. The elevator chain is located inside the chamber and can be 

accessed by removing the lid from the top of your dryer.

 

Connections

 

Elevator Chain

 

Caution!  

Power must be turned off at the external disconnect before entering any part of 

this machine. The red Power Light labeled 

Power

” 

must be off!! A qualified electrician should 

perform any internal testing requiring power on!

 

2)

 To adjust the drive chain you will need to loosen the four mounting screws. The gear motor mounting 

plate is slotted to allow for chain adjustment. Adjust the chain so there is a max of 

1/4” 

vertical movement 

in the chain.

 

CAUTION! Do not over tighten chain, damage to bearings may occur.

 

1) 

To remove the chain guard, unfasten the four 

black sheet metal screws. Be sure to replace the 

guard after adjustment is made.

 

Do 

not operate with Chain 

Guard removed. Serious 

Injury may result!

 

View with chain guard removed

 

Drive Chain Adjustment

 

Chain Guard

 

1

 

3)

 Check that both set screws/ bolts on each sprocket are tight before re

-

installing the Chain guard. A 

1/8” 

and 

3/16”  

Allen Key is required.

 

(4) Mounting Screws 

 

2

 

Pulley Sprocket 

 

(w/ 2 set screws)

 

Drive Sprocket 

(w/ set screw and cap screw)

 

Gear Motor Mounting Plate

 

Pg. 13

Summary of Contents for EconoRed-II Series

Page 1: ...r future reference Date ____ ____ ______ Electrical Drawing Rev ______ Pg VTX Vastex E mail assistance Purchasing Product Info sales vastex com Electrical Support stech vastex com Tech Support Mechani...

Page 2: ...on the heat Allow dryer to cool to 300 F 149 C before switching off conveyor Always turn off power at the main disconnect at the end of production In case an abnormal symptom occurs for example exces...

Page 3: ...conditions so long as the procedures and instructions given in this manual are followed Safe handling transport and storage Before storing the unit follow the shutdown procedure on Pg 11 or on the fro...

Page 4: ...raise the other side and insert both up per and lower bolts and nuts Install remaining bolt on first side and tighten all bolts Use the same procedure for installing rear end section Be sure all end...

Page 5: ...ave a licensed electrician complete the electrical hook up and fill out the warranty card Send it back to Vastex to validate your warranty A wiring diagram has been included with this manual One is al...

Page 6: ...retighten all bolts Recheck belt tracking at front end Note Do not over tighten belt 1 to 2 belt sag is desirable Belt aligner pulley Aligner Bolt Conveyor Front End Drive roller adjustor Adjustor sc...

Page 7: ...nsioner DRIVE ROLLER TENSIONER 4 Drive End RH Side Drive End LH Side CONVEYOR BELT PATH TOP OF BELT BELT RETURN Optional HD Drive After conveyor belt is installed adjust Drive Roller Tensioner to achi...

Page 8: ...d in the trough on the right side of the heater connected with high temperature terminals and stainless steel socket head cap screws J Sensor Vastex uses a mineral insulated Type J Thermocouple mounte...

Page 9: ...gital Volt Meter displays in volts the amount of power going to the belt motor This makes setting and adjusting belt speed much easier A table showing the time associated with voltage can be found in...

Page 10: ...k top of cover and pull straight off Note Cover cannot be removed with the disconnect in the ON position The handle and shaft are keyed to prevent this Installation is the reverse of Removal Be sure t...

Page 11: ...located directly under the heater so it will read a much higher temperature than seen at the garment Set the tem perature several hundred degrees higher to compensate for this difference A non contact...

Page 12: ...h the dryer for more than 10 minutes it is recommended to lower the heat set point to 500 F 260 C It will take approximately 10 minutes to return to operating temperature Periodically check ink temper...

Page 13: ...ator chain is located inside the chamber and can be accessed by removing the lid from the top of your dryer Connections Elevator Chain Caution Power must be turned off at the external disconnect befor...

Page 14: ...ng power available Upon completion of auto tuning the new PID settings are automatically entered into the controller s non volatile memory Manual Mode In the event of a faulty J Sensor the display wil...

Page 15: ...DC Check for obstruction in belt path Check belt tension Check brushes on motor Optional HD mo tor Troubleshooting Controller Error Codes Symptom Cause s Solution s 5 b E r Sensor break error Replace...

Page 16: ...Pg 16...

Page 17: ...licensed trucker shall constitute delivery to Buyer and be determinative of the date and time of shipment and all risk of loss or damage in transit shall be borne by Buyer If the Buyer fails to accept...

Page 18: ...Pg 18...

Page 19: ...Pg 19...

Page 20: ...Pg 20...

Reviews: