Getting started:
Your Exposing Unit has been fully assembled and tested in our factory. Both lid lifting
cylinders have been removed from their upper mounting stud and secured to the side of the
cabinet. Be careful not to damage the rubber vacuum blanket when removing the Exposing
Unit from it's crating.
It is best to keep the lid locked closed when lifting the exposing unit. Carefully remove
the unit from its crate and place it on a suitable surface. It is important that the surface be
flat, an uneven surface can put stress on the glass causing it to crack.
Control Panel
Power Cord
Assembly
Equipment spec tag
Lid Limit Switch
Vacuum Exhaust
Vacuum Pump
(2) Lid Lifting Cylinders
Rubber Vacuum Blanket
Lid
Lid Locking Handle (2)
Install Lid Lifting Cylinders
Remove the acorn nut from the upper cylinder mounting studs located on both sides of the lid.
Unlock and carefully lift lid far enough to slide lifting cylinders onto studs. Replace acorn nuts
onto stud.
Snug only
with a 5/8” wrench. Do not over tighten!
Maximum screen in-
dicator, front corners
DC power supply,
LED lights, (inside)
LED light strip, (3)
Rear screen stops, left stop
vacuum intake
4
Summary of Contents for E2-2128