43
EN
SETTING THE POWER OUTPUT
Before using it for the first time, the power output of the radiator has to be set. This power output
is shown on the ID plate. If the power output is not set correctly, we cannot guarantee the proper
functioning of the radiator.
1-
Press the key while the power is
switched off.
Trip switch
OFF
ON
P
R
O
G
1 2 3 4 5 6 7
2-
Keep the key depressed and switch on
the power.
The coefficient which stands for a certain power
output is, by default, “B00”.
P
R
O
G
1 2 3 4 5 6 7
P
R
O
G
800
3-
Take your finger off the key.
4-
Using the and keys, select the coefficient that corresponds to the power output of the radiator
(see ID plate)
P
R
O
G
1 2 3 4 5 6 7
P
R
O
G
811
Power output (W)
Coëfficient
500
B01
750
B04
1.000
B06
1.250
B08
1.500
B09
1.750
B10
2.000
B11
5-
To confirm, press the key.
The radiator will come on in ‘Auto’ mode
and you’ll hear 2 short beeps.
beep
beep
P
R
O
G
1 2 3 4 5 6 7
P
R
O
G
3
Trip switch
Press the button to put the radiator in operation, in Auto mode.
Press the button again to put the radiator in standby mode.
1 2 3 4 5 6 7
beep
P
R
O
G
1 2 3 4 5 6 7
POWER ON/STANDBY MODE
beep
beep
VASCO handleiding E-Panel LR700001 A4 kopie.indd 43