EN
53
2-
If the room temperature difference is positive, example:
Setting temperature (what you want) = 19°C.
Ambient temperature (what you read on a reliable thermometer) = 21°C.
Difference measured = +2°C.
To correct, simultaneously press the and
buttons for 30 seconds.
Sensor temperature = 21°C
1 2 3 4 5 6 7
P
R
O
G
30 sec.
P
R
O
G
Increase the temperature measured by the ambient
temperature sensor by 2°C by pressing .
In our exemple the measured temperature by the
sensor goes from 21°C to 23°C.
1 2 3 4 5 6 7
P
R
O
G
P
R
O
G
To validate, save the new value and exit the mode, press .
• The reset to zero of the probe calibration
To put the value of the correction to “0”, do the following:
1-
Simultaneously press the and for
30 seconds.
2-
When the temperature measured by the probe
appears, do a press on or for at least
3 seconds.
1 2 3 4 5 6 7
P
R
O
G
30 sec.
1 2 3 4 5 6 7
P
R
O
G
P
R
O
G
3 sec.
3-
Press to exit the probe calibration mode.
In order to a coming back to factory settings, you must hold simutaniously for 8 seconds on , and .
User settings
Comfort temperature
19 °C
Eco-temperature
-3,5 °C
Frost protection temperature
7 °C
Lower limit Comfort temperature
7 °C
Upper limit Comfort temperature
30 °C
Open window detection
Activated
Backlight
L3
Installer settings
PIN code lock
Deactivated
PIN code
0000
Temperature sensor calibration
0,0
RESTORING FACTORY SETTINGS
VASCO handleiding E-Panel LR700001 A4 kopie.indd 53
24/10/19 10:39