Rack Mounting Procedure
1
. Carefully remove the monitor from its packaging.
2. Locate holes in the cabinet front mounting rails corresponding to the holes in the monitor
front panel. Install clip nuts behind the holes in the rails if threaded rails are not provided.
Note:
The mounting rails that run vertically along the inside edges of the front opening of an
EIA rack cabinet can be of two types:
· “Wide” rails have holes spaced 0.5"(12.7 mm) and 1.25"(31.8 mm) on centers, in a repeating
pattern. Wide rails are prevalent in Europe. · “Universal” rails have holes spaced 0.5"(12.7 mm),
0.625"(31.8 mm), and 0.625"(31.8 mm) on centers, in a repeating pattern. Thus, the universal
rails have a hole pattern that contains the wide pattern but provides an additional hole at the
midpoint of the pattern. Universal rails are most prevalent in the US.
3. Install the monitor into the cabinet from the front.
4. Secure the monitor chassis to the cabinet by installing panel mounting screws through the
holes in the monitor front panel and into the rails behind.