Installation
58
Connections at the distribution
The following connections must be
prepared:
Device connection:
Recommendation: 3 x 2.5 mm²,
Sensor cable: RJ12 (in scope of
delivery),
LAN connection.
Do not expose the sensor cable to
mechanical loads.
To keep losses as low as possible, the
line between the storage system and the
connection should have a
maximum
length of 20 m.
Preparation of AC connection to building
network
For connection to the building network,
the 3-wire AC connection line must be
connected to the provided AC connector.
At the end of the connection line, strip
the insulation by 55 mm.