Summary of Contents for POWERplus POWX1770

Page 1: ...ords 6 7 OPERATING INSTRUCTIONS 6 7 1 Instructions before use 6 7 2 Connecting and removing the air hose 6 7 3 Setting the operating pressure 6 7 4 Instructions for use 7 7 5 Switching on and off 7 8 CLEANING AND MAINTENANCE 7 8 1 Venting and bleeding the tank 7 8 2 Changing the oil 7 8 3 Checking the oil level 8 8 4 Checking the safety valve 8 8 5 Thermal Safety 8 8 6 Checking and cleaning the ai...

Page 2: ...POWX1770 EN Copyright 2014 VARO P a g e 2 www varo com 11 NOISE 9 12 WARRANTY 10 13 ENVIRONMENT 10 14 DECLARATION OF CONFORMITY 11 ...

Page 3: ...NT LIST Remove all packaging materials Remove remaining packing and package inserts if included Check that the package contents are complete Check the appliance the power cord the power plug and all accessories for transportation damage Keep the packing materials as far as possible till the end of the warranty period Dispose it into your local waste disposal system afterwards WARNING Packaging mat...

Page 4: ...g in any way Do not use adapter plugs with earthed power tools Unmodified plugs and matching outlets will reduce the risk of an electric shock Avoid body contact with earthed surfaces such as pipes radiators kitchen ranges and refrigerators There is an increased risk of an electric shock if your body is earthed Do not expose power tools to rain or wet conditions If water gets inside a power tool i...

Page 5: ... not allow people who are not familiar with the power tool or these instructions to operate it Power tools are potentially dangerous in the hands of untrained users Maintain power tools Check for misalignment or jammed moving parts breakages or any other feature that might affect the operation of the power tool If it is damaged the power tool must be repaired Many accidents are caused by using poo...

Page 6: ...d to allow sufficient flow to motor Use of an extension cord heavy enough to carry the current the tool will draw is very important Especially when the power source is of great distance An extension cord that is insufficient will cause a drop in line voltage resulting in not starting power loss and causing the motor to overheat 7 OPERATING INSTRUCTIONS 7 1 Instructions before use After removing th...

Page 7: ...ch off the machine press the on off switch 8 CLEANING AND MAINTENANCE Clean the outside of the machine with a moist cloth Regularly check the machine for possible damages and leakage 8 1 Venting and bleeding the tank After each use the tank must be vented and the moist collected in the tank must be drained Turn the machine backwards to gain access to the water outlet valve Loosen the screw careful...

Page 8: ...o each use The level must be equal to the red dot on the gauge glass If the level is below the mark refill the oil 8 4 Checking the safety valve Check the operation of the safety valve prior to each use Make sure that the tank is pressure free The pressure gauge must indicate 0 bar Pull the ring a number of times The pin should move freely Do not use the machine if the pin in the safety valve cann...

Page 9: ...chine Check that the fuses in the meter cupboard are intact Check that no extension cords are used that do not comply with the applicable regulations Check that the work environment is not too cold 9 2 Compressor does not supply air Check that the pressure regulator is adjusted correctly 9 3 Pressure is too high Check if the hose is connected to the correct valve Re adjust the pressure 10 TECHNICA...

Page 10: ...ust penetration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the instructions given in the manual inexpert assembly lightning strike erroneus net voltage This list is not exhaustive Acceptance of claims under warranty can never lead to the prolongation of the warranty period nor ...

Page 11: ...e apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2004 108 EC 2006 42 EC 2000 14 EC Annex VI LwA 96dB A 97dB A Testing Authority Eurofins Modulo Uno Torino IT European harmonized standards including if applicable their amendments up to the date of signature EN1012 1 2010 EN60204 1 2006 EN55014 1 2006 EN55014 2 199...