VARO POWERplus POWX1770 Manual Download Page 6

 

POWX1770 

EN

 

Copyright © 2014 VARO 

P a g e

 | 

6

 

www.varo.com 

 

Only move the machine by lifting the handle. Never pull an attached air hose to move the 
machine. 

 

The working parts of the machine can become hot during operation. Let the machine cool 
down after use. 

 

The machine is equipped with a thermal safety system 

 

Never use gasoline or other flammable liquids to dean the too. Vapours in the tool can be 
ignited by a spark and cause the tool to explode. 

 

If the tank leaks, switch off the machine immediately. Have the machine repaired by an 
authorized technician. 

 

Make sure that the machine is switched off and unplugged and that the tank is pressure 
free before troubleshooting or servicing, or when the machine is not used. 

 

After each use the tank must be vented and the moisture collected in the tank must be 
bled. Not bleeding the tank can lead to leakage and may cause a dangerous situation. 

 

Keep this manual with your compressor. 

6.1 

Extension cords: 

We don not recommend the use of an extension cord with this product as this may result in the 
loss of power and overheating of the motor. An additional air hose should be used instead of 
an extension cord. Improper use of extension cords may cause inefficient operation of tool, 
which can result an overheating. Be sure your extension cord is rated to allow sufficient flow to 
motor. Use of an extension cord heavy enough to carry the current the tool will draw is very 
important. Especially when the power source is of great distance. An extension cord that is 
insufficient will cause a drop in line voltage, resulting in not starting, power loss and causing 
the motor to overheat. 

7  OPERATING INSTRUCTIONS 

7.1 

Instructions before use. 

After removing the compressor from its packaging and if you are certain that it is in perfect 
condition, then you can carry out the following operations: 

 

Assemble the supplied wheels. 

 

Plastic caps at the side of the pumps, must be replaced by the supplied air filters 

 

You have to remove the oil cap and add oil before starting 

7.2 

Connecting and removing the air hose 

 

The machine has been provided with quick couplings 
for the attachment of 1 air hose. 

 

Press the connecting piece of the air hose into the 
connection. 

 

Check whether the air hose is connected properly. 

To remove an air hose, proceed as follows: 

 

Press the connecting piece of the air hose further 
into the connection. 

 

Pull the collar on the connection backward. 

 

Pull out the connecting piece from the connection. 

 

Release the collar 

Before connecting or removing an air hose, always pull the plug from the 
power supply. 

7.3 

Setting the operating pressure 

The set operating pressure can be read from the gauge. 

 

Turn the adjusting knob to the right to increase the operating pressure. 

 

Turn the adjusting knob to the left to reduce the operating pressure. 

Summary of Contents for POWERplus POWX1770

Page 1: ...ords 6 7 OPERATING INSTRUCTIONS 6 7 1 Instructions before use 6 7 2 Connecting and removing the air hose 6 7 3 Setting the operating pressure 6 7 4 Instructions for use 7 7 5 Switching on and off 7 8 CLEANING AND MAINTENANCE 7 8 1 Venting and bleeding the tank 7 8 2 Changing the oil 7 8 3 Checking the oil level 8 8 4 Checking the safety valve 8 8 5 Thermal Safety 8 8 6 Checking and cleaning the ai...

Page 2: ...POWX1770 EN Copyright 2014 VARO P a g e 2 www varo com 11 NOISE 9 12 WARRANTY 10 13 ENVIRONMENT 10 14 DECLARATION OF CONFORMITY 11 ...

Page 3: ...NT LIST Remove all packaging materials Remove remaining packing and package inserts if included Check that the package contents are complete Check the appliance the power cord the power plug and all accessories for transportation damage Keep the packing materials as far as possible till the end of the warranty period Dispose it into your local waste disposal system afterwards WARNING Packaging mat...

Page 4: ...g in any way Do not use adapter plugs with earthed power tools Unmodified plugs and matching outlets will reduce the risk of an electric shock Avoid body contact with earthed surfaces such as pipes radiators kitchen ranges and refrigerators There is an increased risk of an electric shock if your body is earthed Do not expose power tools to rain or wet conditions If water gets inside a power tool i...

Page 5: ... not allow people who are not familiar with the power tool or these instructions to operate it Power tools are potentially dangerous in the hands of untrained users Maintain power tools Check for misalignment or jammed moving parts breakages or any other feature that might affect the operation of the power tool If it is damaged the power tool must be repaired Many accidents are caused by using poo...

Page 6: ...d to allow sufficient flow to motor Use of an extension cord heavy enough to carry the current the tool will draw is very important Especially when the power source is of great distance An extension cord that is insufficient will cause a drop in line voltage resulting in not starting power loss and causing the motor to overheat 7 OPERATING INSTRUCTIONS 7 1 Instructions before use After removing th...

Page 7: ...ch off the machine press the on off switch 8 CLEANING AND MAINTENANCE Clean the outside of the machine with a moist cloth Regularly check the machine for possible damages and leakage 8 1 Venting and bleeding the tank After each use the tank must be vented and the moist collected in the tank must be drained Turn the machine backwards to gain access to the water outlet valve Loosen the screw careful...

Page 8: ...o each use The level must be equal to the red dot on the gauge glass If the level is below the mark refill the oil 8 4 Checking the safety valve Check the operation of the safety valve prior to each use Make sure that the tank is pressure free The pressure gauge must indicate 0 bar Pull the ring a number of times The pin should move freely Do not use the machine if the pin in the safety valve cann...

Page 9: ...chine Check that the fuses in the meter cupboard are intact Check that no extension cords are used that do not comply with the applicable regulations Check that the work environment is not too cold 9 2 Compressor does not supply air Check that the pressure regulator is adjusted correctly 9 3 Pressure is too high Check if the hose is connected to the correct valve Re adjust the pressure 10 TECHNICA...

Page 10: ...ust penetration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the instructions given in the manual inexpert assembly lightning strike erroneus net voltage This list is not exhaustive Acceptance of claims under warranty can never lead to the prolongation of the warranty period nor ...

Page 11: ...e apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2004 108 EC 2006 42 EC 2000 14 EC Annex VI LwA 96dB A 97dB A Testing Authority Eurofins Modulo Uno Torino IT European harmonized standards including if applicable their amendments up to the date of signature EN1012 1 2010 EN60204 1 2006 EN55014 1 2006 EN55014 2 199...

Reviews: