Minimum distance of 200 mm  
between rear of boiler and wall

Vedolux 37 with base frame 
and flue pipe straight up V37

Vedolux 37 with standard flue pipe

Technical data

1. 

Hot water outlet, riser, R32.

2. 

Hot water outlet, return, R32.

3. 

Flue pipe, standard.

4. 

Fan motor.

5. 

Bracket for cleaning tool.

7. 

Upper cleaning hatch.

8. 

Control for bypass damper.

9. 

Firewood hatch.

10.  Ash hatch/draught hatch.

11.  Draining.
12  Base bolts, adjustable.
13.  Connections for cooling coil, 15 mm Cu.
14.  Expansion connection, R25.
15.   Electrical connection, supply, 230V~.
16.  Electrical connection, fan.
17.   Electrical connection, circulation pump for accumulator charging.
18.   Flue pipe straight up, with socket, R25, for support pipe, accessory.
19.  Base frame, accessory.

The manufacturer reserves the right to make changes without notice.

Rear side with fan and electrical connections

C

Weight

empty

320

kg

filled with water

440

kg

Volume

120

litre

Design pressure

1.5

bar

Test pressure

2.15

bar

Pressure drop

water flow 0.54 l/s

10

mbar

Design temperature

110

°C

Operating temperature

max

110

°C

Output wood

moisture 16 ±4%

37/42

kW

oil

50

kW

pellets

42

kW

Combustion chamber

volume

105

litre

depth

550

mm

Length of wood

500

mm

Wood diameter

150

mm

Burning cycle

combustion chamber full, 
moisture 16 ±4%

2.5-3

h

Firewood hatch 

w x h

290 x 235

mm

Chimney requirement

height

min 3.5

m

flue duct recommended

Ø 145

mm

165

cm

2

flue duct min

Ø100

mm

79

cm

2

draught

10

Pa

Flue gas temperature

°C

Flue gas quantity

kg/s

Boiler group as per EN 303-5

3

Summary of Contents for Vedolux 37

Page 1: ...ion operation and maintenance Vedolux 37 08 03 ver 3 RVR 0811 From serial no VB THL product no Arkelstorpsv gen 88 291 94 KRISTIANSTAD Tel 044 22 63 20 Fax 044 22 63 58 info varmebaronen se ww varmeba...

Page 2: ...eaning All flue ducts in the boiler are cleaned from the same hatch at the front of the boiler The hatch is hinged and is opened with a single operation The flue ducts are round which means there are...

Page 3: ...nnection fan 17 Electrical connection circulation pump for accumulator charging 18 Flue pipe straight up with socket R25 for support pipe accessory 19 Base frame accessory The manufacturer reserves th...

Page 4: ...urface area The schematic diagram below shows the Vedolux 37 with the Aqualux and Aqualux UB accumulator tanks plus Accumulator Control 3 For more details refer to the documentation supplied with the...

Page 5: ...draining For filling the shunt valve must be fully open Turbulators The five turbulators are installed in the flue gas pipes as shown in the diagram The purpose of the turbulators is to introduce turb...

Page 6: ...9 20 21 22 23 24 26 15b 17b 16b 20 22 21 25 26 27 28 24 Time relay delayed cutoff 25 Overheating protection 26 Indicator showing triggered over heating protection 27 Thermometer displays the boiler te...

Page 7: ...fter the leaves have come out then wait a few weeks before trimming and splitting the wood During these weeks the leaves wilt and draw out the moisture After another few weeks of drying the wood has 2...

Page 8: ...d hatch followed by the bypass damper If the flue gas temperature increases you know that the firewood has ignited When the firewood has burnt and the flue gas temperature has fallen to be low 120 C t...

Page 9: ...less of the heat escapes with the flue gases One way of telling whether it is time for cleaning is to check the flue gas thermostat It is a good idea to clean the boiler if the flue gas temperature is...

Page 10: ...on the height difference between the highest and lowest points in the system the static head Note that the pressure in the system varies with the boiler tem perature do not add water unnecessarily The...

Page 11: ...increased quickly before charging begins Add a control system Ceramic not correctly positioned If the boiler is new check that the ceramic has not moved during transport There is no need to remove the...

Page 12: ...Draught hatch V 37 1 37 00 60 Handle knob 25 mm 2 28 38 00 01 Manometer 0 4 bar 1 27 38 00 03 Thermometer 0 120 C 1 38 00 30 Flue gas thermometer 50 500 C 1 44 00 02 Pipe cleaner 89 mm 2 44 00 05 Pip...

Reviews: