5
11.03
Vedolux 37
Illustrations may differ from the actual product
Allowing for printing errors and errors on proofs
61
+0.8 -0
13.4
+0.8 -0
930
20.9
3.8
+0.8 -0
0.7
47.6
34.2
50.8
53.8
56.8
n
6
46.7
51
A
A
Technical.data
2
3
12
13
14
1
13
18
19
18
2
1
14
14
Clearance to combustibles.
12” sides and rear, 18” top and 36” front.
Weight
empty �05 lb
Firewood.hatch
w x h 11.4 x 9.3 in
filled with water 9�0 lb
Chimney.requirement
height
11.5 ft
Volume
32 gal
flue duct recommended
Ø 5.�1 in
Pressure
Design
22
psi
25.6 in
2
Test
31
psi
flue duct min
Ø 4 in
Pressure.drop
water flow 0.14 gal/s
0.145
psi
12,6 in
2
Temperature
design
220
°F
draught
0.04 in H
2
O
operating max
220
°F
Flue.gas.temperature
355 °F
Output
wood, moisture content 16 ±4%
126 kBTU
Voltage
115 V, 60 Hz
pellets 143 kBTU
Current
0.3 A
Combustion.chamber
volume
28 gal
Protection.class
IP 21
depth 21.� in
Boiler.group.as.per.EN.303-5
3
Wood
length
20 in
UL391,.CSA-B366.1,.ETLM78-1
diameter
6 in
Certified.by.Guardien.Fire.Test.Labs
Burning.cycle.
combustion chamber full, moisture 16±4% 2.5-3 h
1. Hot water outlet, riser, 1¼” BPT*.
2. Hot water outlet, return, 1¼” BPT*.
3. Flue pipe, standard.
12 Base bolts, adjustable.
13. Connections for cooling coil, 0.6 in Cu.
14. Expansion connection, 1” BPT*.
19. Base frame, accessory.
* Use the delivered NPT adapters for these connections.
The NPT adapter builds 2.2”.
n
6
15.7
4.8
5.3
n
5.9
4,1
6.3