Electrical connection
20
22
21
25
26
27
28
Electrical installation must be in accordance with
the applicable regulations, under the supervision of
an authorised installer.
Electrical connection
The boiler is connected directly to the mains.
The electrical connections are at the rear of the boiler, in the form of
three quick connectors:
15. Mains connection, 230 V~, cable with quick connectors supplied.
16. Fan.
17. Circulation pump, for charging the accumulator system.
Supply
Fan
Circulation pump
YELLOW/GREEN
YELLOW/GREEN
BLUE
BLACK
BLACK
BLUE
15
16
17
Function
Start with the boiler cold.
Set the main switch, 2
0, to the ON-position – the green area must be
visible.
Set the thermostat, “FAN STOP”, 21, to 120°C. The thermostat
detects the flue gas temperature.
Press “FAN START”, 22, the time relay, 24, is activated and the fan
starts.
When the time set for the time relay, 30 minutes, is reache
d, the
contact changes, which means that the fan and the charging pump
for the accumulator system are controlled by the thermostat, 21.
When the firewood is burnt out and the flue gas temperature falls
below the value set for the thermostat, 21, the fan and charging pump
stop running.
If the boiler temperature exceeds 105°C, the overheating protection is
triggered. The fan stops running and the charging pump continues to
operate. If the overheating protection, 25, is triggered, the “ALARM”
indicator, 26, is lit.
An thermostat limits the boiler’s working temperature.
93°C
15. Supply connection, 3-pole connector.
a. cable part, socket.
b. chassis part, plug.
16. Fan connection,
5-pole connector.
a. cable part, plug.
b. chassis part, socket.
17. Connection for charging pump, 3-pole
connector.
a. cable part, plug.
b. chassis part, socket.
18. Terminal block for internal earth connec-
tions.
20. Main switch.
21. Thermostat for fan and charging pump.
22. Fan start, cold boiler.
23. Limit thermostat.
24. Time relay, delayed cutoff.
25. Overheating protection.
26. Indicator showing triggered overheating
protection.
25
15a
16a
17a
18
20
21
22
23
24
26
15b
17b
16b
27. Thermometer, displays the boiler tem-
perature.
28. Pressure gauge showing the water
pressure in the heating system.
Always disconnect the power supply
to the boiler before accessing the
automation cabinet or units powered
by the boiler.
Wiring diagram and control panel