14

VÄRMEBARONEN VEDOLUX 30

Component specification

item prod.no. name 

qty.

25 

12 00 17 

Overheating protection 1-pole, alt. 110°C 

1

21 

12 00 53 

Thermostat 1-pole 100-500°C 

1

 

12 00 09 

Handle thermostat 

1

22 

13 00 31 

Switch 2-pole, auto-return 

1

20 

13 00 32 

Switch 2-pole 

1

18 

16 00 01 

Terminal block 3-pole 

1

 

16 00 06 

End plate 

1

23 

17 00 06 

Relay 1-pole alt. 

1

24 

17 00 22 

Time relay. 

1

26 

19 00 06 

LED 230 V, red, pin 

1

 

23 00 75 

Damper arm 

1

 

23 00 76 

Damper arm lock 

1

31 

23 22 52 

Turbulator 1000 mm 

2

30 

23 22 53 

Turbulator 436 mm 

3

29 50 05 

Cleaning tool bracket 

1

 

30 00 11 

Glass fibre cord 10mm (m) 

1.7

 

30 00 30 

Ceramic fibre paper 1x25mm (m) 

1,1

34 

31 04 02 

Grate front, V-30  

1

34 

31 04 03 

Grate rear, V-30 

1

71 05 06 

Firewood hatch 

1

10 

71 04 94 

Draught hatch, V-30 

1

 

37 00 60 

Handle knob 25 mm 

2

28 

38 00 01 

Manometer 0-4 bar 

1

27 

38 00 03 

Thermometer. 0-120°C 

1

 

38 00 30 

Flue gas thermometer 50-500°C 

1

 

44 00 02 

Pipe cleaner 89 mm 

2

 

44 00 05 

Pipe cleaner 595x80x60/30mm 

1

 

44 00 11 

Spring steel shaft 1500 mm 

2

15b 

44 01 53 

Inlet 3-pole female 

1

 

44 01 54 

Panel fixing 3-pole 

2

17a 

44 01 59 

Plug 3-pole 

1

16b 

44 01 66 

Outlet 5-pole for panel 

1

16a 

44 01 67 

Plug-on contact 5-pole 

1

17b 

44 01 68 

Inlet 3-pole male 

1

15a 

44 01 69 

Plug 3-pole 

1

 

44 02 27 

PowerJet gas lighter 

1

50 00 09 

Fan V-37F 

1

 

70 02 05 

Insulation for cover of flue gas fan 

1

 

70 00 86 

Fan gasket 

1

35 

71 04 53 

Combustion tunnel 

1

 

71 06 69 

Bypass damper 

1

 

71 05 21 

Damper arm 

1

29 

71 02 60 

Turbulator tool 

1

 

71 05 62 

Ash rake 

1

71 04 82 

Cleaning hatch 

1

45 

120006 

Termostat EGO 1-POL, 30-93° 

1

Summary of Contents for Vedolux 30

Page 1: ...Installation operation and maintenance Firewood boiler Vedolux 30 131216 V30 en_mcs rev1...

Page 2: ...at you must or must not do in order to avoid personal injury Tells you what you must or must not do in order to prevent damage or disturbance to the component the burner the process or the surrounding...

Page 3: ...3 V RMEBARONEN VEDOLUX 30 To be completed when the Vedolux 30 is installed Serial number Installation date Installer Tel Other Notes...

Page 4: ...rewood is added Flue cleaning All flue ducts in the boiler are cleaned from the same hatch at the front of the boiler The hatch is hinged and is opened with a single operation The flue ducts are round...

Page 5: ...drop 45 mBar 20 C 1 13 m h 58 mBar 10 C 1 46 m h Weight empty filled with water 290 390 kg kg Volume 100 litre Design pressure 1 5 bar Test pressure 2 15 bar Pressure drop water flow 0 54 l s 10 mbar...

Page 6: ...boiler is supplied with an angled flue pipe a flue pipe running up from the steel pipe is available as an accessory Fasten the flue pipe to the flange on the boiler using the 4 x M8 screws supplied wi...

Page 7: ...il this must be supplemented with a STW STW thermal discharge safety device is used for limiting the temperature by opening a valve normally by circa 97 C and letting cold water enter the cooling coil...

Page 8: ...firewood is burnt out and the flue gas temperature falls below the value set for the thermostat 21 the fan and charging pump stop running If the boiler temperature exceeds 105 C the overheating protec...

Page 9: ...n moisture instead of drying out Ideally the wood should be kept under a roof but in a place where the sun and wind can help dry it The best place for final drying is the boiler room for 2 3 weeks bef...

Page 10: ...ing wood you must open the bypass damper before opening the firewood hatch Only add more firewood when all that is left of the previous load is a layer of embers Constantly topping up with the occasio...

Page 11: ...it is time for cleaning is to check the flue gas ther mostat It is a good idea to clean the boiler if the flue gas tempera ture is approx 25 C higher than the temperature in a clean boiler Open the c...

Page 12: ...hest points in the system the static head If the difference is 5 metres the pressure is 0 5 bar if it is 10 metres the pressure is 1 bar The necessary pressure in the heating system depends on the hei...

Page 13: ...ntrolsystem Ceramicnotcorrectlypositioned Iftheboilerisnew checkthattheceramichasnotmovedduring transport Alsocheckthesealwiththecombustionchamberwalls Highfluegastemperature Tarandsootinthepipes Inco...

Page 14: ...4 03 Grate rear V 30 1 9 71 05 06 Firewood hatch 1 10 71 04 94 Draught hatch V 30 1 37 00 60 Handle knob 25 mm 2 28 38 00 01 Manometer 0 4 bar 1 27 38 00 03 Thermometer 0 120 C 1 38 00 30 Flue gas the...

Page 15: ......

Page 16: ...Varmebaronen UK 11 Back O Hill Stirling FK8 1SH T 01786 849 099 F 01786 849 098 www varmebaronen org info varmebaronen org...

Reviews: