Varmebaronen EK 15 E Installation And Maintenance Manual Download Page 7

7

Värmebaronen EK 15E

menu

s

Menu - User Level

Initial values

Dimensioned values, 

select a curve that provides the desired supply line temperature.

Unknown values - floor heating systems, 

Select a curve that provides a temp. of 40°C for wooden 

joists and 30°C for concrete slab in the supply line temperature on the coldest day.

Unknown values - Radiator system, 

select a curve that provides a 55°C supply temperature for a low 

temperature system on the "coldest day" and a 70°C supply temperature for a high temperate system.
The 'coldest day' is the lowest temperature that normally occurs in the location.

Adjustment of basic setting

For low temperatures, select a higher level. An increase in the room temperature can be limited 
by the thermostats for the radiators or underfloor heating.
For high temperatures, select a lower level.
If the room is not at the desired temperature, additional adjustment is needed. Wait at least one 
day between adjustments so that temperatures have time to stabilize.

 

 

UTK function switched off, see Advanced Service Level row 15.

Alternative temperature

 - -15-+15°C Adjustment

See "Outdoor temperature sensor and alternative heating" in "Electrical installation".
Closed input activates the function. Can be used for night-time reduction, holiday mode or similar, 
see "Electrical installation"; "Alternative temperature".
Function without installed room unit: Shifts, parallel displacement, UTK curve level with a configurable 
number of stages. This corresponds to a change in the room temperature by the approximate 
corresponding number of degrees.

-5

Room unit not installed.

Room unit, current room temperature

 in whole degrees. 15-25°C, display

Room unit not installed.

Room unit, set temperature

 in whole degrees 15-25°C, display.

Adjustments are made using the room unit.

ECO-mode

, adjustment

Standby mode, the electric flow heater holds at a temperature of 7°C.
The pump is turned off but is run every other day.
0: Off
1:  On, the electric flow heater holds at a standby temperature of 7°C. The circulation pump is run every 

other day for two minutes. Output is allowed to step in if external restriction and load guard allow.

0

Delivery setting

Summary of Contents for EK 15 E

Page 1: ...Installation and maintenance EK 15 E Electric flow heater 7 stage 14 7 kW 1212_EK15E_191017_en pwr 1 14 1 15 dsp 1 05 p typ 4...

Page 2: ...sator setpoints UTK Alternative temperature Alternative temperature with room unit Optional Room Unit Over temperature protection Overheating protection Action in the event of a risk of freezing Frost...

Page 3: ...onthat is important for optimum operation Tells you what you should or should not do to avoid personal injury Tells you what you should or should not do to prevent a component the electric flow heater...

Page 4: ...the value is changed the indicator flashes The new value is only applied after confirming by pressing The old value is removed if the row is left with or User level Reading and modification of the mos...

Page 5: ...rent alarm codes according to a rolling schedule Once the cause of the alarm is resolved and is acknowledged with OK the red indicator stops flashing The display will return to its normal display Ackn...

Page 6: ...rve parallel displacement 5 30 adjustment 20 UTK function switched off see Advanced Service Level row 15 Curve higher value provides warmer temperatures for cold outdoor temperatures 20 60 adjustment...

Page 7: ...time to stabilize UTK function switched off see Advanced Service Level row 15 Alternative temperature 15 15 C Adjustment See Outdoor temperature sensor and alternative heating in Electrical installat...

Page 8: ...ut 2 1 4 2 6 3 8 4 10 5 12 6 14 7 kW Current 3 6 05 9 1 12 1 15 1 18 1 21 2 A 7 UTK function switched off see Advanced Service Level row 15 UTK min Limitation of the supply line temperature Adjustment...

Page 9: ...16 above At Absolute temperature the selected temperature should not exceed 10 C 10 Manual activation of rows 19 and 20 Adjustment 0 Off 1 Limited to 15 minutes 0 Manual activation test run of output...

Page 10: ...see Advanced Service Level line 14 For testing and service the connection delay and output connect disconnect can be temporarily sped up see Service level rows 1 and 2 The electric flow heater should...

Page 11: ...few more times The pressure in a heating system varies with the temperature Do not add water unnecessarily Draining If the heating system needs to be drained of water the electric flow heater must fi...

Page 12: ...ontain corrosion limiting additives Suitable water line quality Alkalinity 60 mg l to avoid corrosion Carbonic acid content 25 mg l increase the risk of corrosion Sulphate contents 100 mg l may accele...

Page 13: ...and must be laid so that water pockets cannot form The opening pressure of the safety valve is determined by the component in the system that tolerates the lowest pressure System principles The figure...

Page 14: ...conductor is connected in terminal 4 10 Electrical installation Electrical installation shall be carried out in accordance with the applicable regulations by an authorized electrical installer or by...

Page 15: ...er 14 Overheating protection 15 Contactor power group three 16 Heating element output group three 8 4 kW 17 Heating element for output group two 4 2 kW 18 Heating element for output group one 2 1 kW W...

Page 16: ...ain only when the temperature has dropped below the limit Selectable in Advanced Service level rows 16 and 7 Low boiler temperature Boiler temperature lower than 7 C The electric flow heater s tempera...

Page 17: ...ard during resistance measurement When the boiler is energized voltage is measured in the sensor s connection points at the PCB Boiler temperature C k V C k V C k V 5 141 9 4 7 40 30 3 7 75 8 2 2 3 10...

Page 18: ...tage size 2 1 kW Current stage 3 A Ingress protection rating IP x1 Flow requirements recommended t 10 C min max t 25 5 C 0 35 0 2 0 7 litres sec litres sec Pressure drop Volume 3 6 litres Design press...

Page 19: ...panel 1 700414 Overlay 1 6 210206 Temperature sensor 1 11 440090 Capacitor 1 12 130010 Switch 1 120009 Knob for switch 1 700223 Shaft for switch 1 13 180023 Miniature circuit breaker 1 14 120025 Over...

Page 20: ...V rmebaronen AB Arkelstorpsv gen 88 SE 291 94 Kristianstad Tel 46 44 22 63 20 www varmebaronen se www varmebaronen com info varmebaronen se...

Reviews: