Variotech NSE Manual Download Page 3

 

Manual and Data Sheet NSE Version 1.0 

 

Variotech – Emergency power supply unit NSE Version 1.0

 

Date: 10.01.14, Page 3 of 7 

 

Training of the installation and operation personnel: 

The operator may only use people for installation and commissioning, which have 
the basic rules of accident prevention and safety knowledge and have read and 
understood the safety instructions in this manual. 

Warranty and liability management: 

Warranty and liability claims will be lost if the control is not used as intended or if 
any damage due to non-observance of the operating instructions or if the 
installation and operating personnel have not been trained properly. 

Intended use: 

The application of ENA3 safety controls are provided solely lift systems.  
The control may not be used in of other systems or particular in industrial plants. 
The safety control ENA3 may only be used for the case defined in EN81 Annex 3, 
to prevent of an unintendend movement of the car from a standstill. 

Commercial data: 

Name:    

 

Emergency Power Supply Unit NSE 

Packaging Unit:  

1 Piece 

Customer Tariff: 

85044081 

Weight / Piece    

5N 

 
 
 

Product details: 

Function: 

1.  NSE provides an uninterrupted supply of power for the control unit ENA3 and the 

trigger coil (24VDC) of the actuator (A3 brake element) for about 10 seconds after a 
power failure. 

2.  After these 10 seconds, the NSE switches off the supply voltage for the ENA3 and 

the coil in order not to discharge the backup battery. 

3.  An emergency rescue button on the box can be pushed to activate the battery again 

for additional 15 minutes which supplies the ENA3 and the coil.  
During this time, it is possible to make an emergency rescue drive of the lift. 

4.  This can be repeated multiple times for another 15 minutes, if required. 

 

 

Summary of Contents for NSE

Page 1: ...and liability management 3 Intended use 3 Commercial data 3 Product details 3 Function 3 Product description 4 Layout and connections 4 Technical Details 4 Environmental conditions 5 Conditions of us...

Page 2: ...er a 24V power supply and battery backup NSE The power supply NSE requires an input voltage of 13 6 V DC galvanically isolated from the mains power supply The power supply NSE generates the charging v...

Page 3: ...in of other systems or particular in industrial plants The safety control ENA3 may only be used for the case defined in EN81 Annex 3 to prevent of an unintendend movement of the car from a standstill...

Page 4: ...oltage of 24VDC from the 12V battery This only requires a single 12V battery Reverse polarity protection and automatic reset fuse at the battery clamp Automatic lowering of the supply voltage of the A...

Page 5: ...itable power supply would be Meanwell MDR 40 12 Terminal 3 Connection for the potential free output contact relay power ok of the power supply Terminals 4 5 Connection for a safety relay contact of th...

Page 6: ...continuity tester If the battery is OK the two terminals have the same potential Check the correct connection of the emergency rescue button to terminals 14 and 15 with a continuity tester Terminal 1...

Page 7: ...talled in a control box On request the unit can also be supplied already mounted in an industrial plastic housing IP65 The complete system ENA3 NSE BOX consists of a pre wired and pre assembled ENA3 c...