Date: 10.01.14, Page 2 of 7 

 

 
In preparing this manual we have used the utmost care, but we cannot guarantee the accuracy of 
this manual, because mistakes cannot be avoided 100%. 
 
The contents of this manual can be changed anytime without notice. For improving information we 
will be grateful. 
 
This safety control is designed exclusively for use in a lift control system as power supply for an A3-
brake element and may be used only as specified in this manual. 
 
This description contains the information necessary for the intended use of the power supply unit NSE. 
 
Knowledge about the safety of the operating field 'Lift' is assumed. 
These skills are fundamental for the understanding of this description.

 

General: 

The power supply unit NSE is destined for use as power supply of an A3 safety control and the A3 
brake element. 

It guarantees an uninterrupted supply of power for the control unit ENA3 and the 24V trigger coil of the 
actuator (A3 brake element). This prevents an unwanted triggering of the actuator caused by a power 
failure. 

The NSE consists of a pre-wired and pre-assembled ENA3 controller, a 24V power supply and battery 
backup (NSE). 

The power supply NSE requires an input voltage of 13.6 V DC, galvanically isolated from the mains 
power supply.  

The power supply NSE generates the charging voltage for a 12V battery and an uninterruptible 
buffered voltage of 24VDC for the A3 safety control as well as for the A3 brake element (coil). 

Legend

Particularly important information in the manual are identified as follows: 

DANGER!  +  WARNING!

 

This notice must be strictly observed. The sign warns of imminent danger, which can 
cause serious injury and death. 

 
ATTENTION! 

This note indicates attention to a hazard and informs of appropriate precautions to 
prevent minor injuries and property damages. 

 

IMPORTANT! - INFO! 

This note presents situations that can lead to damage of equipment or facilities, and 
provides tips for proper application and also provides information on key passages and 
other special features.

 

Safety guidelines:

 

The safety instructions are an important part of the operating manual. In consequence of 
non-compliance of the instructions, all warranty claims and warranties, as well as 
potential liability claims are lost. Moreover all regulations on accident prevention for lifts 
must be observed. All local rules must be taken into account to prevent damage due to 
improper handling with voltages and currents. Especially concerning protection measure 
and correct earthing. 

Summary of Contents for NSE

Page 1: ...and liability management 3 Intended use 3 Commercial data 3 Product details 3 Function 3 Product description 4 Layout and connections 4 Technical Details 4 Environmental conditions 5 Conditions of us...

Page 2: ...er a 24V power supply and battery backup NSE The power supply NSE requires an input voltage of 13 6 V DC galvanically isolated from the mains power supply The power supply NSE generates the charging v...

Page 3: ...in of other systems or particular in industrial plants The safety control ENA3 may only be used for the case defined in EN81 Annex 3 to prevent of an unintendend movement of the car from a standstill...

Page 4: ...oltage of 24VDC from the 12V battery This only requires a single 12V battery Reverse polarity protection and automatic reset fuse at the battery clamp Automatic lowering of the supply voltage of the A...

Page 5: ...itable power supply would be Meanwell MDR 40 12 Terminal 3 Connection for the potential free output contact relay power ok of the power supply Terminals 4 5 Connection for a safety relay contact of th...

Page 6: ...continuity tester If the battery is OK the two terminals have the same potential Check the correct connection of the emergency rescue button to terminals 14 and 15 with a continuity tester Terminal 1...

Page 7: ...talled in a control box On request the unit can also be supplied already mounted in an industrial plastic housing IP65 The complete system ENA3 NSE BOX consists of a pre wired and pre assembled ENA3 c...