ProStar 363 Control Manual 

- 21 -

 03-914947-26:.2

 

Overview Window 

Click on the 

 button: the 

Status

 

Overview

 window is 

displayed and contains three tabs: 

 

General

: displays the synopsis of the instrument, where 

some current values can be read (signal, emission or 
excitation wavelengths, etc.). 

 

 

Not ready:

 contains the not ready information sent by the 

instrument. 

 

Events:

 contains the events that have occurred on the 

instrument. 

Summary of Contents for ProStar 363

Page 1: ...Varian Inc 2700 Mitchell Drive Walnut Creek CA 94598 1675 USA Varian Inc 2005 03 914947 26 2 ProStar 363 Fluorescence Detector Control Galaxie Driver Manual...

Page 2: ...the Varian ProStar 363 Fluorescence Detector 5 Configuring the Synopsis 7 Building a Method 9 Creating a New Method 9 Control Method Section for the Varian ProStar 363 Fluorescence Detector 12 Starti...

Page 3: ...neral This document describes the configuration of the Varian ProStar 363 Fluorescence Detector driver It also explains how to build a control method for this driver how to start and view a running ac...

Page 4: ...communicate with the ProStar 363 module an RS232_Interface or a RS232_PC communication bus must be configured on the acquisition server The parameters of the bus to must be the following Stops 1 Stop...

Page 5: ...e Detector Click on the button corresponding to the Varian ProStar 363 driver and the configuration screen appears Two sub sections allow you to configure the instrument Communication and Hardware The...

Page 6: ...ProStar 363 Control Manual 6 03 914947 26 2 Communication Window Select from the list the name of the RS422 Bus the detector has been connected to Hardware Window...

Page 7: ...ration screen Properties wizard A graphic of the devices that comprise the system is displayed in the synopsis screen To configure the synopsis as the real instrument configuration move each module th...

Page 8: ...ProStar 363 Fluorescence Detector Galaxie Configuration Manager Screen Galaxie Chromatography Data System screen NOTE Once the system has been created and correctly configured it must be associated w...

Page 9: ...nal results To initially set up a method it is not necessary to define all of the sub method sections however you must fill in the instrument controls section prior to staring an acquisition 1 To crea...

Page 10: ...created for a particular system When starting an acquisition the name of the system that performs the acquisition must be correct since method access is limited only to those methods associated with...

Page 11: ...raphy Data System The next step is the definition of each of the method sections The control section must be defined in order to start an acquisition In the following part of this guide only the contr...

Page 12: ...he new method is created select the control section in the lower part of the browser The following screen appears Press the button to display the System Control Method Advanced Tools window to send th...

Page 13: ...n Parameters Control Select from the list the Time Constant to be used for smoothing of the detector Four choices are available 0 1 0 5 2 0 4 0 and 8 0 seconds Generally small Time Constant gives fast...

Page 14: ...uisition Quick Start and sequence Check Lock detector keyboard during runs to lock the detector keyboard Program the evolution of the Excitation and Emission wavelengths The Excitation parameter is th...

Page 15: ...has been correctly programmed an analysis can be started The next section briefly describes how to start an acquisition Quick Start Single Acquisition 1 Press the button In the Quick Start window sele...

Page 16: ...m the Injection Volume the Vial position and the Rack number if required must be entered Other parameters associated with each acquisition channel can be entered in the Channel X tab 3 Click on the St...

Page 17: ...amples and the sequence name 2 The sequence is displayed Complete the sequence information columns refer to the Galaxie Chromatography Data System User s Guide The Method Name the Run Name the Run ID...

Page 18: ...ProStar 363 Fluorescence Detector Status Click on the button corresponding to the ProStar 363 driver and the detector status screens will appear It contains two sub sections Status and GLP Click on t...

Page 19: ...Signal Offset displays the offset setting in the active method PMT Voltage displays the photomultiplier voltage setting in the active method Em Bandwidth displays the emission bandwidth setting in the...

Page 20: ...k on the button when the lamp is turned off to turn it on Click on the button when the lamp is turned on to turn it off GLP Window This tab is active only if no acquisition is in progress Lamp GLP Dat...

Page 21: ...dow is displayed and contains three tabs General displays the synopsis of the instrument where some current values can be read signal emission or excitation wavelengths etc Not ready contains the not...

Reviews: