![Vari Lite VL500 Wash Luminaires User Manual Download Page 59](http://html1.mh-extra.com/html/vari-lite/vl500-wash-luminaires/vl500-wash-luminaires_user-manual_3514633059.webp)
M
ENU
S
YSTEM
: M
ENU
O
PERATION
4
02.9685.0001 0
01-March-2006
43
The menu system is a programmable set of commands used to configure, address, operate, and test the
luminaire. The menu system is controlled at the Menu Display available at the enclosure input panel.
The menu system has seven main functions which are referred to as “1st level.” Within these main
functions, there can be up to four additional sub-functions (levels 2 thru 5), making five total levels.
To enter the menu system, first press [Menu]. The functions displayed will be 1st level functions.
Scroll through the 1st level functions by pressing [Up] / [Down] arrows. Once the desired function
appears in the display, press [Enter]. You are now at the 2nd level. Once again, press the [Up] /
[Down] arrows to scroll through 2nd level functions. Press [Enter] to access 3rd level functions and so
forth. When the highest level for the function is reached, [Up] / [Down] arrows can be pressed to enter
a value or select a toggle activation such as On/Off. Press [Enter] to store the value or select an action.
For example:
Default State
The menu display’s default state during normal operation is to display the DMX address. After 10
seconds of inactivity at the display, it will change to the default state.
After longer periods of inactivity, the backlight in the menu display will switch to its off state. The
default state for this feature is 5 minutes, however, different time lengths can also be programmed. If
display turns off, always hit [Menu] to reactivate.
To program a different time length for menu off feature:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until
Config
(Configuration) appears. Press [Enter].
Step 3. Press [Up] / [Down] arrows to access
Display
. Press [Enter].
Step 4. Press [Up] / [Down] arrows to select either
30 Sec
(30 seconds),
5 Min
(5 minutes),
10
Min
(10 minutes), or
ON
(on indefinitely). Press [Enter] to set.
Shortcuts
A few button combinations are provided as shortcuts for frequently used menu functions. These
shortcuts are as follows:
•
Pressing [Enter] and [Up] at the same time = Lamp On (Arc fixtures only)
•
Pressing [Enter] and [Down] at the same time = Lamp Off (Arc fixtures only)
•
Pressing [Menu] and [Up] at the same time = Recalibrate
•
Pressing [Menu] at Power up interrupts calibration. See
“Program Starting Address Without
Calibrating Luminaire” on page 20
for more information.
•
Pressing [Menu] and [Down] at the same time = flips display (when auto orientation is off).
•
1st Level
Test
ALL SEQ
RUN TEST
2nd Level
3rd Level
Summary of Contents for VL500 Wash Luminaires
Page 1: ......
Page 13: ...FOREWORD 02 9685 0001 0 01 March 2006 xi...
Page 14: ...VARI LITE VL500 WASH LUMINAIRE USER S MANUAL xii 01 March 2006 02 9685 0001 0...
Page 38: ...VARI LITE VL500 WASH LUMINAIRE USER S MANUAL 22 01 March 2006 02 9685 0001 0 Notes...
Page 56: ...VARI LITE VL500 WASH LUMINAIRE USER S MANUAL 40 01 March 2006 02 9685 0001 0 Notes...
Page 82: ...VARI LITE VL500 WASH LUMINAIRE USER S MANUAL 66 01 March 2006 02 9685 0001 0 Notes...
Page 83: ......