background image

4

VL800 EVENTPROFILE

QUICK START GUIDE

FIGURE 4. 

 SAFETY ANCHOR

When hanging the luminaire in a side hang position, natural convection and the designed direction of the inlet 
and exhaust cooling fans dictate that the inlet should be closest to the fl oor and the exhaust should be towards 
the ceiling. This eliminates the possibility of one luminaire blowing exhaust air into the inlet of the luminaire next 
to it when the luminaires are side-by-side.

If the luminaires are stacked on top of one another in a side hang, a 45° enclosure orientation with the fan inlet 
closest to the fl oor.

MENU OPERATION

LCD DISPLAY AND MENU SYSTEM

The VL800 Eventprofi le Luminaire’s LCD Display and Menu System provide local control for accessing the fol-
lowing fi xture’s settings: 

•  Address – to set the DMX address

•  

Confi gure – various parameter settings, set LED, movement, display, reset defaults

•  

DMX – change the map, set address,

•  

Fixture – fi xture status, ReCal, reboot, software version, view fi xtures hours, crossload, service

•  

Test – to test functions of parameters

•  

Manual Preset – to set the intensity, all functions

The menu system is controlled at the Menu Display available at the enclosure input panel. If there are multiple 
luminaires in a system, any settings or changes would need to be made at each LCD Menu as desired.

MENU CONTROLS

The menu system is controlled by an [MENU], [ENTER] and two Arrow (

▲▼

) buttons. 

LCD Display

Shows all data

and settings

Ÿź

Arrow Keys (up / down)

Menu navigation / data selections

[MENU] Button

Used to access main menu paramters

[ENTER] Button

Used to select or change a setting or

data value

Summary of Contents for EVENTPROFILE VL800

Page 1: ...wer connector is supplied however you will need to purchase or construct a cable ap propriate for your application FIGURE 1 POWER CONNECTOR Depending on the application the luminaire s AC input cable...

Page 2: ...This maximum limit applies to the luminaire daisy chain only Your system or console may require fewer luminaires on a single data link path Consult your console documentation for more information To c...

Page 3: ...of the base by inserting quick lock fasteners into the holes of the base and tighten fully clockwise Step 3 Hang the xture to the support through clamp and faster the screws faster the safety cable th...

Page 4: ...ystem provide local control for accessing the fol lowing xture s settings Address to set the DMX address Con gure various parameter settings set LED movement display reset defaults DMX change the map...

Page 5: ...digit Step 4 Once all digits are set in DMX address press Enter to set Step 5 DMX will display and is saved STATUS BAR The Status Bar is present at all times and displays luminaire operational inform...

Page 6: ...Gobo Wheel 2 19 Gobo Wheel 1 Control Gobo Wheel 1 Control Iris 20 Gobo Wheel 2 Gobo Wheel 2 Frame 1A 21 Gobo Wheel 2 Control Gobo Wheel 2 Control Frame 1B 22 Iris Iris Frame 2A 23 Frame 1A Frame 1A F...

Page 7: ...7 VL800 EVENTPROFILE QUICK START GUIDE...

Page 8: ...ious operating problem immediately discontinue using the xture Never turn on and off the unit time after time The housing lenses and or the ultraviolet lter must be replaced if they are damaged Discon...

Reviews: