background image

3

VL800 EVENTPROFILE

QUICK START GUIDE

HANGING THE LUMINAIRE

The VL800 EVENTPROFILE Luminaire can be hung hori-
zontally or vertically from any structure designed to work 
with the type of load created Clamp and Quick lock fasten-
er or other mounting hardware are required. Many compat-
ible truss hooks are available from diff erent manufacturers 
for your particular needs.

One Quick-lock fastener per luminaire is required. If 
mounting method does not use truss hooks, two attach-
ment points per luminaire, are required. Always ensure 
the diameter of safety cable is at least 4 mm, which can 
support at least 12 times the weight of the unit.

To install mounting hardware and brackets:

Step 1. 

Bolt each clamp to the Omega holder with screw 
and lock nut through the hole in the holder as shown in 

FIGURE 3

.

NOTE:  

Various types of truss hooks can be used. The Clamp (as shown) as well as many other standard hooks, 

can be ordered separately. 

Step 2. 

Faster the omega holders on the bottom of the base by inserting quick-lock fasteners into the holes of 
the base and tighten fully clockwise.

Step 3. 

Hang the fi xture to the support through clamp and faster the screws, faster the safety cable through 
the bottom of the base and over the support. 

WARNING!

  Ensure that the bracket locking mechanism is fully seated after the bracket is installed on the 

luminaire.

FIGURE 3. 

 INSTALLING BRACKETS ON LUMINAIRE ENCLOSURE

To install luminaire in truss:

Step 1. 

Lift luminaire into mounting position.

Step 2. 

Secure in place with clamp handle. Ensure clamp handle hardware that Quick-lock fastener hook in 
place (eg. wing bolt) is properly tightened and that luminaire is fully supported.

Step 3. 

Attach safety cable (as required) as follows (refer to 

FIGURE 4

):

a. 

Loop safety cable at least once around safety cable anchor point rod.

b. 

Loop safety cable at least once around truss/pipe and secure around pipe.

SAFETY CABLE: 

Recommended for hanging installations. May be required by local codes. Safety cable sold 

separately.

NOTE:

 Truss hooks shown are sold separately. Truss and pipe by others.

Step 4. 

Make sure hanger is disengaged so luminaire moves freely.

Step 5. 

Connect power and data cables.

Summary of Contents for EVENTPROFILE VL800

Page 1: ...wer connector is supplied however you will need to purchase or construct a cable ap propriate for your application FIGURE 1 POWER CONNECTOR Depending on the application the luminaire s AC input cable...

Page 2: ...This maximum limit applies to the luminaire daisy chain only Your system or console may require fewer luminaires on a single data link path Consult your console documentation for more information To c...

Page 3: ...of the base by inserting quick lock fasteners into the holes of the base and tighten fully clockwise Step 3 Hang the xture to the support through clamp and faster the screws faster the safety cable th...

Page 4: ...ystem provide local control for accessing the fol lowing xture s settings Address to set the DMX address Con gure various parameter settings set LED movement display reset defaults DMX change the map...

Page 5: ...digit Step 4 Once all digits are set in DMX address press Enter to set Step 5 DMX will display and is saved STATUS BAR The Status Bar is present at all times and displays luminaire operational inform...

Page 6: ...Gobo Wheel 2 19 Gobo Wheel 1 Control Gobo Wheel 1 Control Iris 20 Gobo Wheel 2 Gobo Wheel 2 Frame 1A 21 Gobo Wheel 2 Control Gobo Wheel 2 Control Frame 1B 22 Iris Iris Frame 2A 23 Frame 1A Frame 1A F...

Page 7: ...7 VL800 EVENTPROFILE QUICK START GUIDE...

Page 8: ...ious operating problem immediately discontinue using the xture Never turn on and off the unit time after time The housing lenses and or the ultraviolet lter must be replaced if they are damaged Discon...