6

VL3600 PROFILE IP

 

Quick Start Guide

 REV A 06/28/22

Adjust the luminaire head to the illustrated state and ready for air tightness test.
Remove three pressure relief valves with a 16mm hex sleeve screwdriver. 

 

 

After removing the three pressure relief valves, lock any two pressure relief valve holes with two
M12 waterproof screws, and insert the air hose of the air tightness tester into the remaining
pressure relief valve hole. Power on the air tightness tester, adjust the parameters, run the test
and wait for the test results.

 

After the test is passed, remove the two M12 waterproof screws and put the three pressure relief valves
back in place.

Summary of Contents for 74817-001

Page 1: ...compatible connector is supplied however you will need to purchase or construct a cable appropriate for your application Depending on the application the luminaire s AC input cable may require a diffe...

Page 2: ...that they will not interfere with luminaire head and yoke movement CURRENT VERSUS VOLTAGE TABLE 1 provides the luminaire s current draw at specific voltages Total luminaire current is calculated with...

Page 3: ...needs A minimum of two hooks per luminaire is required If mounting method does not use truss hooks two attachment points per luminaire are required Install mounting hardware and brackets Step 1 Insta...

Page 4: ...ing bolt is properly tightened and that luminaire is fully supported Step 3 Attach safety cable as required as follows a Loop safety cable at least once around safety cable anchor point rod b Loop saf...

Page 5: ...e waterproof silicon ring for after service Unscrew the screws of the luminaire arm covers with a Torx screwdriver to open the luminaire arm covers no need to move the waterproof silicon ring for afte...

Page 6: ...g the three pressure relief valves lock any two pressure relief valve holes with two M12 waterproof screws and insert the air hose of the air tightness tester into the remaining pressure relief valve...

Page 7: ...utton and then quickly press the UP Down UP DOWN buttons in 2s to unlock the screen QUICK REFERENCE MENU KEY SHORTCUTS MENU KEY SHORTCUTS FUNCTION Holding Menu at Power up Bypass Calibration Menu Up R...

Page 8: ...Wheel 3 Rotate Index High Byte DMX CHANNEL PARAMETER 26 VLFX Gobo Wheel 3 Rotate Index Low Byte 27 VLFX Gobo Wheel 3 Control 28 Iris 29 Frame 1A 30 Frame 1B 31 Frame 2A 32 Frame 2B 33 Frame 3A 34 Fram...

Page 9: ...Control 24 VLFX Gobo Wheel 3 25 VLFX Gobo Wheel 3 Rotate Index High Byte 26 VLFX Gobo Wheel 3 Rotate Index Low Byte 27 VLFX Gobo Wheel 3 Control Table 3 16 BIT ENHANCED MODE DEFAULT DMX CHANNEL PARAME...

Page 10: ...responsibility of the user to adequately protect supply source with a correct size and type circuit breaker and not overload circuits WARNING This unit has a battery Replace only with the correct typ...

Page 11: ...tch the power requirements of the fixture The fixture must be earthed grounded to the appropriate conductor Do not operate fixture outside the specified ambient temperature range Do not connect the fi...

Reviews: