VL3600 PROFILE IP
Quick Start Guide
REV A 06/28/22
Adjust the luminaire head to the illustrated state and ready for air tightness test.
Remove three pressure relief valves with a 16mm hex sleeve screwdriver.
After removing the three pressure relief valves, lock any two pressure relief valve holes with two
M12 waterproof screws, and insert the air hose of the air tightness tester into the remaining
pressure relief valve hole. Power on the air tightness tester, adjust the parameters, run the test
and wait for the test results.
After the test is passed, remove the two M12 waterproof screws and put the three pressure relief valves
back in place.