background image

8

VL3600 PROFILE IP

 

Quick Start Guide

 REV A 06/28/22

DMX 

CHANNEL 

PARAMETER

1

intensity High

2

intensity Low 

3

Pan High

4

Pan Low

5

tilt High

6

tilt Low

7

Focus High

8

Focus Low

9

Zoom High

10

Zoom Low

11

cyan

12

Yellow

13

Magenta 

14

ctO Wheel

15

color adjustment

(color Wheel 2)

16

color Wheel 1

17

color Wheel 1 control 

18

Gobo Wheel 1 (Fixed)

19

Gobo Wheel 1 control

20

Gobo Wheel 2

21

Gobo Wheel 2 rotate/index 

High Byte

22

Gobo Wheel 2 rotate/index 

Low Byte

23

Gobo Wheel 2 control

24

VLFX (Gobo Wheel 3)

25

VLFX (Gobo Wheel 3)  

rotate/index High Byte

DMX 

CHANNEL 

PARAMETER

26

VLFX (Gobo Wheel 3)  

rotate/index Low Byte

27

VLFX (Gobo Wheel 3)  

control

28

iris

29

Frame 1a

30

Frame 1B

31

Frame 2a

32

Frame 2B

33

Frame 3a

34

Frame 3B

35

Frame 4a

36

Frame 4B

37

Frame rotate

38

Prism 1 (triangular)

39

Prism 1 index/rotate High 

Byte

40

Prism 1 index/rotate Low 

Byte

41

Prism 2 (Flat)

42

Prism 2 index/rotate  

High Byte

43

Prism 2 index/rotate  

Low Byte

44

Frost

45

Strobe

46

Future use channel

47

Programmers channel

48

Fan control

49

Luminaire control

TAbLE 2. 

16-bIT MODE

Quick reFereNce dMX MaPS

The short form DMX maps are available on the following pages. Visit the product page for full DMX maps.
• 

table 2. 16-Bit

• 

table 3. 16-Bit enhanced Mode (default)

Summary of Contents for 74817-001

Page 1: ...compatible connector is supplied however you will need to purchase or construct a cable appropriate for your application Depending on the application the luminaire s AC input cable may require a diffe...

Page 2: ...that they will not interfere with luminaire head and yoke movement CURRENT VERSUS VOLTAGE TABLE 1 provides the luminaire s current draw at specific voltages Total luminaire current is calculated with...

Page 3: ...needs A minimum of two hooks per luminaire is required If mounting method does not use truss hooks two attachment points per luminaire are required Install mounting hardware and brackets Step 1 Insta...

Page 4: ...ing bolt is properly tightened and that luminaire is fully supported Step 3 Attach safety cable as required as follows a Loop safety cable at least once around safety cable anchor point rod b Loop saf...

Page 5: ...e waterproof silicon ring for after service Unscrew the screws of the luminaire arm covers with a Torx screwdriver to open the luminaire arm covers no need to move the waterproof silicon ring for afte...

Page 6: ...g the three pressure relief valves lock any two pressure relief valve holes with two M12 waterproof screws and insert the air hose of the air tightness tester into the remaining pressure relief valve...

Page 7: ...utton and then quickly press the UP Down UP DOWN buttons in 2s to unlock the screen QUICK REFERENCE MENU KEY SHORTCUTS MENU KEY SHORTCUTS FUNCTION Holding Menu at Power up Bypass Calibration Menu Up R...

Page 8: ...Wheel 3 Rotate Index High Byte DMX CHANNEL PARAMETER 26 VLFX Gobo Wheel 3 Rotate Index Low Byte 27 VLFX Gobo Wheel 3 Control 28 Iris 29 Frame 1A 30 Frame 1B 31 Frame 2A 32 Frame 2B 33 Frame 3A 34 Fram...

Page 9: ...Control 24 VLFX Gobo Wheel 3 25 VLFX Gobo Wheel 3 Rotate Index High Byte 26 VLFX Gobo Wheel 3 Rotate Index Low Byte 27 VLFX Gobo Wheel 3 Control Table 3 16 BIT ENHANCED MODE DEFAULT DMX CHANNEL PARAME...

Page 10: ...responsibility of the user to adequately protect supply source with a correct size and type circuit breaker and not overload circuits WARNING This unit has a battery Replace only with the correct typ...

Page 11: ...tch the power requirements of the fixture The fixture must be earthed grounded to the appropriate conductor Do not operate fixture outside the specified ambient temperature range Do not connect the fi...