C
HAPTER
3. M
AINTENANCE
P
ROCEDURES
3-27
02.9631.0010
CONFIDENTIAL
15 Jan 98
Test 40 - Error Code History
Entering test setting 40 for a selected luminaire provides a history of error
codes for that luminaire compiled since testing began or prior error code
messages were cleared, whichever is more recent. Error codes are
displayed one at a time in the console board control window. Pressing
[NEXT ERR] advances display to next error code.
Test 41 - Error Code Clear
Entering test setting 41 for a selected luminaire clears all prior messages
for that luminaire. Once a luminaire error has been corrected, clearing
prior error codes allows the test to be rerun and verify no new error codes
are generated.
Test 88 - Thumbwheel Reading
Entering test setting 88 causes the thumbwheel setting for the selected
luminaire to be displayed in the console board control window. Once test
setting has been entered, the luminaire thumbwheel can be reset and the
new setting will be displayed in the console board control window. When
test is complete, return thumbwheel to original setting.