Regulations 

All local regulations, including those that refer to national and European standards, 
must be complied with during fi tting, e.g. the Danish building regulations for small 
houses, BR-S 98, published by the National Agency for Enterprise and Construction. 

Minimum distance to combustible materials, such as fl oors, walls or furniture

 

Varde In-Line 55: Behind: 35 cm Side: 35 cm Above the fl oor: 30 cm In front: 110 cm

Floor materials

If there is a fl oor made of combustible material by the fi replace insert, this must 
naturally be covered by a panel of non-combustible material such as a steel plate, 
glass sheet, Dutch brick or artifi cial slate. The fl oor panel must extend at least 15 
cm from the sides of the insert and at least 30 cm from the front. We recommend 
however 50 cm at the front. 

Fresh air intake

A supply of fresh air must be available in the room in which you install the fi replace 
insert, e.g. via ventilation grills in the walls. It must not be possible to block these 
grills. You should also be aware that any extraction ventilators (cooker hoods or the 
like) in the same room as the insert may cause problems in relation to the chimney 
updraught. 

Damper

 

In some cases it may be necessary to install a damper in the chimney, so that the 
updraught can be adjusted. This can be especially useful on very windy days. There 
must always be at least 20 cm

2

 of free passage via the chimney. Consult your dealer 

or chimney sweep for advice.

The fi replace insert is suitable for connection to a fl ue gas collector.

Always ensure that the fl ue gas connector and chimney can be cleaned. Consult 
your dealer or chimney sweep for advice. 

Nominal operation and a room temperature of 20˚C provides: 

Varde In-Line 55: Smoke mass fl ow: 6.8 g/sec Flue gas temperature: 274°C

Important information

 DANSK

  

|  

ENGLISH

  

|  

DEUTSCH  

|  

FRANÇAIS

VARDE IN-LINE 55 

Nominal heat output: 7 kW (4-9 kW) 

Heats up to: 30-100 m

2

 

Weight: 102 kg  

Smoke outlet: Ø 15 cm 

Exterior dimensions: height 54.5 x width 68 x depth 37 cm

Exterior dimensions of front frame: height 71.5 x width 79.5 cm

Specifi cations 

APERTURE DIMENSIONS FOR 
STANDARD FRAMES:

Height:  See the sketches under 

“Building in*”

Width: 70-75 cm
Depth: Min. 40 cm

D

B

H

Summary of Contents for IN-LINE 47

Page 1: ...1 1 In Line VARDE IN LINE 47 VARDE IN LINE 55 Monteringsmanual Fitting instructions Einbauanleitung Instructions de montage...

Page 2: ...nye pejseindsats F r De p begynder monteringen af Deres nye pejseindsats skal De s rge for at De har det rette v rkt j og materiale MED DERES NYE PEJSEINDSATS F LGER Monteringsvejledning Installation...

Page 3: ...wpilen der angiver r gretningen gennem r ret Isolerrundt om exr ret medisoleringsbatts Ladde verste2 3cmv refri tilefterf lgendefastst bningaf exr ret sepkt 8 Klarg ring 1 Murv rk F r montering af pej...

Page 4: ...er Fastg r evt indsatsen i bunden af pejsen med et par karmskruer betonskruer el lign gennem de 2 store huller i bunden Montering 5 Placering Pejseindsatsen er nu klar til montering Tag vermikulitplad...

Page 5: ...st 15 cm ud fra indsatsens sider og mindst 30 cm ud fra forsiden Vi anbefaler dog 50 cm foran Frisklufttilf rsel I det rum hvor indsatsen skal monteres skal De s rge for at der er tilstr kkelig friskl...

Page 6: ...efter behov for at sikre optimal udnyttelse af pejseindsatsen Opt nding Opt nding i pejseindsatsen er meget nemt takket v re 2 trinsgrebet T nd op luk l gen og s t grebet i opt ndingspositionen Luk l...

Page 7: ...VARDE IN LINE 47 VARDE IN LINE 55 12 VARDE IN LINE 47 VARDE IN LINE 55 13 DANSK ENGLISH DEUTSCH FRAN AIS Fitting instructions In Line...

Page 8: ...rde Ovne Congratulations on your new replace insert Before you begin tting your new replace insert make sure you have the right tools and materials THE FOLLOWING ITEMS ARE INCLUDED WITH YOUR NEW FIREP...

Page 9: ...must be level and stable and must not be cracked or porous Cast a new founda tion if necessary 2 Access hatch 20 30 cm To connect the replace insert to the chimney you must rst install the exible tub...

Page 10: ...ready for use Replace the vermiculite plates and the base slab in the insert in the order shown Fill in the top 2 3 cm with replace mortar to x the tubing in place Your replace insert is now ready fo...

Page 11: ...dalsobeawarethat anyextractionventilators cookerhoodsorthe like inthesameroomastheinsert maycauseproblemsinrelationtothechimney updraught Damper Insomecasesit maybenecessarytoinstalladamperinthechimne...

Page 12: ...he handle should point downward with the Varde Ovne logo the right way up Replace the door and adjust if necessary Door Maintenance DANSK ENGLISH DEUTSCH FRAN AIS When stoking it is recommended that t...

Page 13: ...VARDE IN LINE 47 VARDE IN LINE 55 VARDE IN LINE 47 VARDE IN LINE 55 24 VARDE IN LINE 47 VARDE IN LINE 55 25 In Line DANSK ENGLISH DEUTSCH FRAN AIS Einbauanleitung...

Page 14: ...Gegebenheiten M glicherweise ist es aufgrund besonderer Bedingungen erforderlich von der Einbauanleitung abzu weichen z B hinsichtlich des Rauchrohrtyps der beim Einbau verwendet werden muss ACHTUNG...

Page 15: ...lex Rohr stecken Anschlie end Flex Rohr mit Spannband o festspannen 4 Rauchrohr DANSK ENGLISH DEUTSCH FRAN AIS Es ist wichtig dass Schornstein und Rohr von innen gereinigt werden k nnen Darum muss m g...

Page 16: ...Platten und Bodenstein wieder in gezeigter Reihenfolge in den Einsatz legen Zur Befestigung des Flex Rohres werden die oberen 2 3 cm mit Kaminm rtel ausge f llt Jetzt kann der Kamin in Gebrauch genom...

Page 17: ...nnen Drosselklappe IneinigenF llenist amSchornsteineineDrosselklappeerforderlich damit derZugreguliert werdenkann DieskanninsbesondereinRegionenmit starkemWindn tigsein Esmuss immerwenigstens20cm2 ung...

Page 18: ...herum stehen T r wieder einh ngen und wenn n tig ausrichten Ofent r Wartung DANSK ENGLISH DEUTSCH FRAN AIS Beim Nachlegen empfehlen wir erst dann die T r zu ffnen und neues Holz nachzulegen wenn im F...

Page 19: ...VARDE IN LINE 47 VARDE IN LINE 55 VARDE IN LINE 47 VARDE IN LINE 55 36 VARDE IN LINE 47 VARDE IN LINE 55 37 In Line DANSK ENGLISH DEUTSCH FRAN AIS Instructions de montage...

Page 20: ...in que votre insert sera correctement mont Dans certaines conditions il peut tre indispensable de vous carter des instructions de montage par exemple en ce qui concerne le type de conduit de fum e uti...

Page 21: ...l aide d un collier de serrage ou autre 4 Conduit de fum e DANSK ENGLISH DEUTSCH FRAN AIS Il est important que vous puissiez nettoyer l int rieur de la chemin e et du conduit C est pourquoi il peut tr...

Page 22: ...t Reposez les plaques de vermiculite et la pierre de fond dans l insert dans l ordre indiqu Remplissez les 2 3 cm du dessus l aide de mortier pour foyer a n de xer le conduit L insert peut maintenant...

Page 23: ...letiragedelachemin e Registreder glage Danscertainscas lapr senced unregistreder glagedanslachemin eest requisea n depermettreler glagedutirage Celapeut notamment s av rern cessairelesjoursde grandven...

Page 24: ...e correctement orient Remontez la porte et ajustez au besoin Porte Entretien DANSK ENGLISH DEUTSCH FRAN AIS Lors du rechargement il est recommand d attendre qu il ne reste plus que des braises dans la...

Page 25: ...VARDE IN LINE 47 VARDE IN LINE 55 48 Varde Ovne A S Kongevej 246 Tiset DK 6510 Gram Denmark Tel 45 74 82 00 03 Fax 45 74 82 00 05 VARDE IN LINE 47 VARDE IN LINE 55 www vardeovne dk...

Reviews: