1 µA
0.1 µA
Resolution
Range
+/- (1% + 2)
0.1 mA
0.01 mA
0.001 A
4000 µA
400 µA
400 mA
40 mA
4 A
0.1 A
10 A
+/- (1.2% + 3)
Accuracy
DC current
Protection :
mA range : fuse F1 Ø5x20mm, F 0.5A H 250V
10A range : fuse F2 Ø5x20mm, F 10A H 250V
1 µA
0.1 µA
Resolution
Range
+/- (1.2% + 5)
0.1 mA
0.01 mA
0.001 A
4000 µA
400 µA
400 mA
40 mA
4 A
0.01 A
10 A
+/- (1.5% + 3)
Accuracy
AC current
0.1 Hz
0.01 Hz
Resolution
Range
(0.5% + 3)
0.01 kHz
0.001 kHz
0.1 kHz
100 Hz
10 Hz
10 kHz
1 kHz
100 kHz
0.001 MHz
1 MHz
0.1 MHz
10 MHz
0.1 %
0.1 ~ 99.9%
(0.5% + 3)
Accuracy
Frequency
Protection :
mA range : fuse F1 Ø5x20mm, F 0.5A H 250V
10A range : fuse F2 Ø5x20mm, F 10A H 250V
+/- (1% + 2)
+/- (1.2% + 3)
+/- (1.5% + 5)
+/- (1.5% + 5)
+/- (1.2% + 5)
+/- (1.5% + 3)
+/- (2% + 5)
+/- (2% + 5)
(0.5% + 3)
(0.5% + 3)
(0.5% + 3)
(0.5% + 3)
(0.5% + 3)
For indication only
3/6