6.2.2 Drain Pump
The pump is a sealed unit and should not be dismantled. Instructions for removal /
replacement are as follows.
1) Place a bucket below the pump, to catch any
water remaining in the housing or pipework.
2) Remove the two screws holding the pump cover
& lift clear.
3) Undo the three screws holding the pump body
to the feed & drain manifold, and remove it - any
water trapped in the pump will be released at this
point.
4) Fit the replacement pump by following the above
steps in reverse order. Ensuring that the O-ring
surrounding the impeller housing is correctly
seated, and that it mates correctly with the feed /
drain manifold.