![Vanward GD4838S-G Assembly, Use And Care Manual Download Page 22](http://html.mh-extra.com/html/vanward/gd4838s-g/gd4838s-g_assembly-use-and-care-manual_854134022.webp)
22
LP GAS System
Contact your gas supplier for a special regulator for bulk gas that fuels other
appliances.
Gas Consumption
Total gas consumption of this grill with the burner(s) on “MAX” Table 1 below.
Table 1
Burner Type
BTU/HR
Main Burners
12,000
Side Burner
12,000
Locating the Grill
This gas appliance is designed and certified for outdoor use only. Do not
operate the grill inside a building, garage, recreation vehicle, screened porch
or any enclosed area. Keep the grill away from windy areas, but keep the grill
in a well-ventilated area. Do not obstruct the flow of combustion and ventilation
air around the grill.
Warning:
Do not place the grill under overhead, unprotected
combustible surfaces.
Clearance to Combustible Construction
A minimum clearance of 36 in. from the sides of the grill and a minimum
clearance of 36 in. from the back of the grill to adjacent vertical combustible
constructions must be maintained. However, the manufacturer strongly
suggests a 6 ft. clearance of the grill to combustible constructions.
Clearance to Noncombustible Construction
A minimum clearance of 36 in. from the back of the grill above the cooking
surface to noncombustible constructions is required to allow the grill hood to
open completely. A minimum of 36 in. clearance to the sides of the grill above
the cooking surface to noncombustible constructions is recommended. The
grill can be installed directly next to noncombustible construction below the
cooking surface.
Checking orifice alignment with burners
Orifices may shift during assembly and movement; therefore, check the orifice
alignment with the burners according to the following illustrations before lighting.
Fig. 25 Main Burner and Orifice Relationship