background image

 

3.0

 

Battery Charging 

 

CAUTION: 

The  battery  charger  should 

never

  be  used  as  an  AC  adapter  by  plugging  the  RF 

power  source  connector  into  the  battery  charger  connector.  The  Sealer  will  not 
function properly and the charger may be damaged. 

3.1 

Plug  the  battery  charger  into  an  AC  power  source  (wall  outlet)  and  verify  that  the  green 
power “ON” indicator light is illuminated. 

Power status is represented by the green power status indicator light as follows: 

Power Indicator Light Activity 

Description 

Green light not illuminated 

Charger not plugged into AC 
power source (wall outlet). 

Green light flashing 

Battery Pack deeply discharged.  
See Note in Section 3.2 for how 
to proceed. 

Green light continuously 
illuminated 

Charger ready for charging.  
Plug in battery pack 

 

NOTE:

 

Check to see that the power cord plug matches the power receptacle for the country in 
which  the  battery  charger  is  being  used.    If  it  does  not,  or  if  the  green  power  “ON” 
indicator  light  does  not  illuminate,  contact  an  authorized  Vante®  SEBRA  service 
center. 

3.2 

Once the battery pack is removed from the RF power source (Section 2.0), plug the battery 
pack’s red and black connector into the matching connector on the battery charger. 

CAUTION: 

The battery pack and charger connectors are keyed to properly engage. Be sure that 
the RED battery pack connector is engaged into the RED battery charger connector, 
and the  BLACK into the BLACK.  If they do not easily engage, do not  attempt  to 
force the connectors together. Improper battery connection will result in damage to 
the battery pack and/or charger and will void the warranty. 

 

CAUTION: 

Charge the battery pack 

only 

with the Vante® SEBRA Model 2389 Rapid Charger 

to ensure safety and prevent battery damage. 

 
 

Summary of Contents for SEBRA 2389

Page 1: ...Model 2389 RAPID CHARGER For use with the Model 2380 Mini Hand Held Tube Sealer INSTRUCTION MANUAL ...

Page 2: ......

Page 3: ...i 1997 SEBRA Vante Inc 3480 E Britannia Dr Suite 120 Tucson AZ 85706 USA Telephone 520 881 6555 Fax 520 323 9055 Toll Free 877 565 5557 Part No VT 23892000 01 Rev B ...

Page 4: ...lated procedures are used for purposes other than those stipulated herein validation of the specific application should be obtained otherwise Vante SEBRA assumes no liability or obligation nor guarantees product performance The contents of this manual are not to be construed as license to operate under nor a recommendation to infringe upon any patents Personnel using the product do so at their own...

Page 5: ...mponent Identification 1 2 0 Battery Pack Removal from Power Source 2 3 0 Battery Charging 3 4 0 Battery Pack Insertion into Power Source 5 Table of Figures Figure 1 1 Components of Rapid Charger 1 Figure 2 1 Accessing and Removing the Battery Pack 2 Figure 4 1 Opening Battery Compartment Door 5 Figure 4 2 Battery Connector Location 5 Figure 4 3 Battery Installation 6 Figure 4 4 Battery to Power S...

Page 6: ......

Page 7: ...arger for use with battery packs of the Model 2380 Mini Hand Held Tube Sealer Model 2380 The Rapid Charger comes with a power cord 1 2 Component Identification Shown in Error Reference source not found are the component parts of the Rapid Charger Model 23891000 01 Charger Assembly Power Cord Model number depends upon country of use Figure 1 1 ...

Page 8: ...ead and or tubing are dry and clean to eliminate the possibility of further arcing Turn the power source on and continue sealing If the battery low condition is indicated again and arcing has not occurred then it is time to charge the battery pack 2 2 Prior to battery pack removal turn the power switch to the off position Disconnect the sealing head and RF power cable and remove the power source f...

Page 9: ...ack NOTE Check to see that the power cord plug matches the power receptacle for the country in which the battery charger is being used If it does not or if the green power ON indicator light does not illuminate contact an authorized Vante SEBRA service center 3 2 Once the battery pack is removed from the RF power source Section 2 0 plug the battery pack s red and black connector into the matching ...

Page 10: ...ry pack on charger Charger will automatically switch to Fast Charge when appropriate Fast Charge Amber light continuously illuminated Charger in fast charge mode Float Charge Amber light flashes every second Fast charging complete battery pack ready for use CAUTION If Fast Charge period amber charge status light is continuously illuminated exceeds 6 hours disconnect battery pack from battery charg...

Page 11: ...en the battery compartment door on the power source case by sliding the latch to the right See Figure 4 1 Figure 4 1 4 2 Position the battery connector as shown in Figure 4 2 CAUTION Use only with battery packs equipped with a Positive Thermal Cutout PTC device and or approved for use with Vante SEBRA Model 2380 Figure 4 2 ...

Page 12: ...rs are keyed to engage properly Be sure that the RED battery pack connector is engaged into the RED power source connector and the BLACK into the BLACK If they do not engage easily do not attempt to force the connectors together Improper battery connection will result in damage to the RF power source and will void the warranty Figure 4 4 4 5 Close and latch the battery compartment door If desired ...

Reviews: