www.fmiproducts.com
125501-01B
21
5. Press in control knob and turn counter-
clockwise
to the PILOT position
(see Figure 31). The ignitor will spark
once. Keep control knob pressed in for 5
seconds. If control knob does not pop up
when released, contact a qualified service
person or gas supplier for repairs.
Note: You may be running this heater for
the first time after hooking up to gas sup
-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This
will allow air to bleed from the gas system.
6. Turn control knob clockwise
to
OFF position. Press in control knob and
turn counterclockwise
to PILOT
position. This will light pilot. Pilot is at
-
tached to rear of burner. If needed, repeat
this process until pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
7. Keep control knob pressed in for 30 sec
-
onds after lighting pilot. After 30 seconds,
release control knob.
Note: If pilot goes out, repeat steps 3
through 7.
OPERATION
Continued
Figure 31 - Control Knob and Ignitor
Button Location
PILOT
OFF
LO
HI
Control Knob
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
8. Slightly press and turn control knob coun-
terclockwise
to desired heating
level. The burner should light. Set control
knob to HI or LO.
WARNING: Do not operate
heater between PILOT and HIGH
positions.
9. To leave pilot lit and shut off burners only,
turn control knob clockwise
to the
PILOT position.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
to OFF
position.
2. Close equipment shutoff valve (see Figure
15, page 15).
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 5 under
Lighting
Instructions
beginning on page 20.
2. Press control knob and light pilot with
match.
3. Keep control knob pressed in for 30 sec
-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 8
under
Lighting Instructions,
above.