Overview 
The Vantage DMX DALI GATEWAY 
(DDG) simultaneously processes 
information to/from 

DMX

 and/or 

DALI

 

devices. The DDG station provides a 
full DMX universe of 512 channels, from 
which 64 channels may be used for 
DALI control. The information is 
transmitted via Ethernet, in controlled 
packets, to the Vantage Controller 
which acts as the central control point. 
The Vantage Controller conversely 
transmits controlled packets back to the DDG to be distributed 
to each connected bus. The Vantage controller manages the 
information, load status and levels; making the interface simple 
to use. 
  

This product is very versatile and its capabilities and limits must 
be fully understood to use effectively. Read all of these 
instructions before installing. 

 
DMX DALI GATEWAY Features/Operations 

 

Standard RJ45 Ethernet terminal connector 

 

Phoenix type screw terminals 

o

 

Easy power and bus connections 

 

4-LED Communication Status Indicators 

o

 

Ethernet, Bus 1, Bus 2, and Bus 3 

 

Firmware Updateable*  

 

Support for DMX and/or DALI devices simultaneously 

o

 

Bus 2 is DMX 

o

 

Bus 3 is DALI 

 

Reset Button 

o

 

Boot Loader Mode

: Standard Press & Release, do not 

hold – … 

 

Reboots station into boot loader mode, LEDs may 
flicker and then go off. 

 

Boot loader mode is used when upgrading 
firmware. 

 

Re-power the station to exit boot loader mode. 

o

 

Factory Reset

: Press and hold just over 4 seconds – … 

 

Resetting to factory settings - LEDs go off until the 
station reboots to factory settings - all load 
channels are set back to default.  

 

This also resets the IP address to factory settings.  

 

Reference Standards

 

o

 

IEC 61547. 

 

Equipment for general lighting purposes – EMC immunity 
requirements 

o

 

IEC 61000-3-2 

 

Electromagnetic compatibility (EMC) – Part 3-2: Limits – 
Limits for harmonic current emissions (equipment input 
current   16A per phase) 

o

 

EN 55015 

 

Limits and methods of measurement of radio disturbance 
characteristics of electrical lighting and similar equipment 

o

 

IEC/EN 62386-101 

 

Digital addressable lighting interface – Part 101: General 
requirements - System 

o

 

IEC/EN 62386-102 

 

Digital addressable lighting interface – Part 102: General 
requirements – Control gear 

o

 

IEC/EN 62386-207 

 

Digital addressable lighting interface – Part 207: Particular 
requirements for control gear – LED modules (device type 
6) 

o

 

ANSI E 1.3 

 

Entertainment Technology – Lighting Control Systems – 0 
to 10V Analog Control Specification 

o

 

ANSI E 1.11 

 

Entertainment Technology – USITT DMX512-A – 
Asynchronous Serial Digital Data Transmission Standard 
for Controlling Lighting Equipment and Accessories 

o

 

ANSI E 1.20 

 

Entertainment Technology-RDM-REMOTE Device 
Management over USITT DMX512 Networks – Lighting 
Control Systems – 0 to 10V Analog Control Specification 

 
 

System Specifications 

Description 

Specification 

Dimensions, HWD 

3.5” x 2.8” x 2.4” 

90mm x 72mm x 62mm 

Weight 

4.8oz - 136g 

Input Voltage 

12Vdc | 320mA – 48Vdc | 80mA 

Mounting 

35 mm DIN Rail (EN 50 022: 1977) 

Connects to Vantage Via 

Ethernet, RJ45 – 10/100Mbit 

Maximum Power Draw 

500mA 

Minimum Power Draw 

40mA 

Max. DDG Loads (channels) 

512 

ModBus RTU Bus 1 

RTU MODBUS (

not supported

**

DMX Bus 2, full DMX universe 

Support for NSC, SIP, RDM 

512 DMX channels – NSC, SIP, RDM 

NSC  –   Null Start Code 

SIP 

–  System Information Packet 

RDM – Remote 

Device 

Management 

DALI Bus 3  

64 channels, 125mA power supply 

DMX / DALI Channels 

Duplicate DMX and DALI channel assignments 

are shared on both buses 

DALI Groups 1-16 

Control from 1 to 16 DALI groups 

(see 

Using DALI Groups,

 pg5) 

4-LED Communication 

Status Indicators 

1 LED for each: 

Ethernet, Bus 1, Bus 2, and Bus 3 

Local Contact (n.o.) input 

Stand-alone mode, not used with InFusion 

application 

Ambient Operating Temperature 

min. -40°C to max. 40°C 

 min. -40°F to max. 140°F 

Ambient Operating Humidity 

non-condensing environment 

CE Certified 

YES 

 

*Firmware Update 

Before installing

 the Vantage DDG, make sure the firmware has 

been updated to the latest release. See 

Steps to Update 

Station Firmware

 on page 5 in this document. After a firmware 

update the station’s new 

factory setting 

IP address is

 

192.168.1.225. H

owever, updating firmware does not change the 

IP address to the factory setting. Only a factory reset will 
change the IP address to the factory setting – see 

Reset Button

 

(previous column). 
 
**Setting ModBus RTU, Bus 1 to DMX 
It is possible, through the 

DGM Device Config

 tool, to set the 

ModBus RTU

, Bus 1 to DMX512. Setting the 

ModBus RTU

, Bus 1 

to DMX512 only mirrors Bus 2 on the InFusion System. Design 
Center only supports one DMX512 universe on each DDG 
station and cannot distinguish between Bus 1 and Bus 2 on the 
same station. Sending a command to any DMX channel will 

simultaneously

 control loads assigned to that channel number 

on both Bus 1 and Bus 2 DMX universes. 
  
DMX-DALI-GATEWAY / DGM Configuration Steps 
The 

DGM Configuration

 software is built-in the DDG station 

and is accessed by connecting to the station’s IP address via 
most internet browsers.  
 
NOTE: The 

DGM Config

 tool has to connect to the DDG station 

via the default IP address when the station is in default mode 
or an assigned IP address if the station is not in default mode 
and has been assigned a new IP address. The steps below 

may

 

require the default IP address of 

192.168.1.225 

be substituted 

with 

192.168.1.4 -or-

 if the station has previously been assigned 

a new IP address, and is not in default mode, substitute the 
new IP address. 
 Power on the station with the correct power supply. 
1.

 

The station comes with a static IP Address of 192.168.1.225 
or 192.168.1.4. The 192.168.1.225 IP address is from newer 
firmware releases. 

2.

 

Follow the a. or b. steps below depending on the local 
network. 
 

 

a.

 

If the local network 

is not on

 the 192.168.1.x subnet and 

the DDG station 

is set to default mode

i.

 

Configure the local network’s router to reserve a 
static IP address for the DDG station – record for later 
use. 

ii.

 

Disconnect the computer from the main network. 