Installation and Servicing:
The VL36BN gas fireplace is equiped with a 120VAC, 60Hz.
optional blower.
The circulating fan has been designed to increase the ef-
ficiency of convection heat by providing a very quiet air
flow over the combustion chamber of the fireplace and
discharging heated air into your living space.
The fan can be controlled by turning the black knob (lo-
cated below the control compartment) clockwise to slow
the fan down, and counterclockwise to speed the fan up.
The blower is automaticly controlled by a thermally
activated switch positioned behind the burner and below
the burner tray which will activate when the Fireplace has
heated up, (automatically 15-20 minutes), and will prevent
the fan from operating when the fireplace is cold.
NOTE:
ALL electric work on this fireplace must conform
with local building codes, and CSA 2.22 electrical code
requirements.
Section 9:
Optional fan kit
For Servicing a fan installation,
follow these steps.
1).
Remove the door, and buckles from bottom of the door,
and swing the door upright until the upper three (3) tabs
loosen.
2).
Remove the front decorative trim from the glass tray,
the glass media, and the glass burner tray itself. The burner
glass tray is removed by removing all 11-bolts from around
the burner.
3).
Undo the gas line, and the burner tray (9-bolts) all
around, and remove the tray to the outside of the fireplace.
4).
The blower compartment is placed on the right-hand
side, back corner of the fireplace, behind the separation
wall.
The blower is supplied with a mounting bracket which has
two (2) holes for bolting down the fan support bracket.
Slide the blower into the fan blower compartment and bolt
it down to the support.
Figure 31.
Sliding the blower into place.
Figure 30.
Location of blower.
WARNING
Electrical grounding instructions. This appliance is
equipped with a three-pronged (grounding) plug for
your protection against shock hazzard and should be
plugged directly into a properly grounded three-e-
pronged receptacle. Do not cut or remove the ground-
ing prong from the plug.
AVERTISSEMENT
Électriques instructions de mise à la terre. Cet
appareil est équipé d'un à trois broches (mise à la
terre) prise pour votre protection contre les chocs
hazzard et doit être branchée directement dans une
prise à trois broches. Ne pas couper ou enlever la
broche de terre de la fiche.
Part. No.
VL36BN-Man-072414-A
VL36BN Gas Fireplace
VANOX Fireplace Inc.
Page 21
Summary of Contents for Nova VL36BN
Page 19: ...SIT IPI Valve Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 19...
Page 20: ...Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 20...
Page 26: ...Notes Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 26...
Page 27: ...Notes Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 27...