Confirming proper venting of Appliance.
To check for proper drafting use this procedure.
1). Place unit in operation and allow to run for approximately
(5)-minute to establish a up-draft.
2). Using a match or something that will produce smoke,
place it up to the opening of the draft hood and verify that
the flame or smoke is being drawn into the draft hood. If the
flame or smoke is blown away from the draft hood open-
ing. You may have to re-check the venting and verify there
is a minimum of 12’-0” feetof venting, or check the house for
negative pressure.
Installation with 4”diameter aluminum venting into an exist-
ing type “A” wood fireplace Chase.
Spill Switch
Relief Opening
Figure 9.
VL36BN
Wiring diagram with millivolt system.
Figure 10.
VL36BN
installation where a wood fireplace
chase exists.
Figure 9a.
PVEB
Wiring diagram.
Part. No.
VL36BN-Man-072414-A
VL36BN Gas Fireplace
VANOX Fireplace Inc.
Page 10
Summary of Contents for Nova VL36BN
Page 19: ...SIT IPI Valve Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 19...
Page 20: ...Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 20...
Page 26: ...Notes Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 26...
Page 27: ...Notes Part No VL36BN Man 072414 A VL36BN Gas Fireplace VANOX Fireplace Inc Page 27...