background image

25

106516

OWNER’S MANUAL

O

F

F

PI

LOT O

N

L O

I H

OPERATING
FIREPLACE

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A.

This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B.

BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some gas
is heavier than air and will settle on
the floor.

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor's phone. Follow the
gas supplier's instructions.

C.

Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn by
hand, don't try to repair it, call a quali-
fied service technician. Force or at-
tempted repair may result in a fire or
explosion.

D.

Do not use this appliance if any part
has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part
of the control system and any gas con-
trol which has been under water.

FOR YOUR SAFETY

READ BEFORE

LIGHTING

LIGHTING

INSTRUCTIONS

1.

STOP! Read the safety information in
column one.

2.

Open lower louver panel.

3.

Disconnect the wire that runs from TH
to TPTH from the valve.

4.

Turn off all electric power to the
fireplace.

5.

Push in gas control knob slightly and
turn clockwise 

 to “OFF”.

TO TURN OFF GAS

TO APPLIANCE

1.

Open lower louver panel.

2a.

If Using Optional ON/OFF Switch:

Turn ON/OFF switch to “OFF”.

2b.

If Using Optional Hand-Held Re-
mote:

 Set selector switch in the OFF

position to prevent draining battery.

Figure 56 - Control Valve

Piezo
Ignitor

Gas Control Knob Variable Control Knob

OPTIONAL REMOTE

OPERATION

Note:

 All remote control accessories must

be purchased separately (See Accessories
on pages 34 and 35). Follow instructions
included with the remote control.

Thermostat Control Operation

(Optional GHRCT Only) The thermostat
control setting on the remote control unit
can be set to any comfort level between HI
and LO. The burners will turn on and off
automatically to maintain the comfort level
you select. The ideal comfort setting will
vary by household depending upon the
amount of space to be heated, the output of
the central heating system, etc.

NOTICE: You must light the pilot
before using the hand-held re-
mote control unit. See 

Lighting

Instructions.

6.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including near
the floor. If you smell gas, STOP! Fol-
low “B” in the safety information in
column one. If you don't smell gas, go
to the next step.

7.

The pilot is located by the main burner
and should not require accessing for
lighting.

8.

Turn gas control knob counterclock-
wise 

 to “PILOT”.

9.

Push in gas control knob all the way and
hold. Immediately light the pilot by re-
peatedly depressing the piezo spark ig-
nitor until a flame appears. Continue to
hold for about one (1) minute after the
pilot is lit. Release gas control knob and
it will pop back. Pilot should remain lit.
If it goes out, repeat steps 5 through 8.
• If gas control knob does not pop up when

released, stop and immediately call your
service technician or gas supplier.

• If the pilot will not stay lit after sev-

eral tries, turn the gas control knob
to “OFF” and call your service tech-
nician or gas supplier.

10. Reconnect the wire that runs from TH

to TPTH from the valve.

11. Turn on all electric power to the

fireplace.

12. Turn gas control knob counterclock-

wise 

 to “ON”.

13. This valve is equipped with a HI/LO

feature. Set fireplace input as desired.

14. Close lower louver panel.

3.

Turn off all electrical power to the ap-
pliance if service is to be performed.

4.

Push in gas control knob slightly and
turn clockwise 

 to “OFF”.

5.

Close lower louver panel.

Shutting Off Burners Only (pilot
stays lit)

You may shut off the burners and keep the
pilot lit by doing one of the following:

1.

Turn gas control knob clockwise

 to the PILOT position.

2.

Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.

Remove glass door (see Removing/Re-
placing Glass Door
, page 22).

2.

Follow steps 1 through 8 under Light-
ing Instructions
.

3.

Depress gas control knob and light pi-
lot with match.

4.

Keep gas control knob pressed in for 30
seconds after lighting pilot. After 30 sec-
onds, release gas control knob. Now fol-
low steps 10 through 14, column 2.

5.

Replace glass door (see Removing/Re-
placing Glass Door
, page 22).

Continued

Summary of Contents for BHDV34PB

Page 1: ...is tance or additional information consult a qualified installer ser vice agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may result ca...

Page 2: ...he glass door must be properly seated and sealed If this unit is not properly installed by a qualified service person with glass door properly seated and sealed gas leakage can occur Carbon Monoxide P...

Page 3: ...t PIEZO IGNITOR This fireplace has a piezo ignitor This sys tem requires no matches batteries or other sources to light fireplace Figure 1 Vanguard Direct Vent Fireplace BHDV Series Glass Door Assembl...

Page 4: ...3 34 3 4 34 1 4 20 Vertical Termination 19 Horizontal Termination CLEARANCES Minimum clearances to combustibles for the fireplace are as follows Back and sides 0 mm Perpendicular walls 6 152mm Floor...

Page 5: ...ept where stated otherwise Combustible material may be flush with the top front of fireplace with a maxi mum thickness of 3 4 Do not recess venting terminals into a wall or siding You must install a v...

Page 6: ...bove paved side walk or a paved driveway located on public property 84 inches 2133mm minimum M clearance under veranda porch deck 12 inches 305mm minimum N clearance above a roof shall extend a minimu...

Page 7: ...ination It is important to select the proper length of vent pipe for the type of termination you choose It is also important to note the wall thickness For Horizontal Termination Select the amount of...

Page 8: ...bows to the appliance adaptor with pipe seams oriented towards the wall or floor Twist lock Procedure The female ends of the pipes and fittings have four locking lugs indentations These lugs will slid...

Page 9: ...f the vent cap Position the vent cap in the center of the 7 1 2 or 10 hole on the exterior wall with the arrow on the vent cap pointing up Insure proper clearance of 1 to combustibles is maintained At...

Page 10: ...use with corner installation UP Horizontal Venting See information in Figure 17 for Vertical V and Horizontal H maxi mums and minimums The same amounts apply for flexible venting Note Figure 16 applie...

Page 11: ...max 8 min 8 min 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 19 Horizontal Termi...

Page 12: ...uired clearances air space to combus tibles when passing through ceilings walls roofs enclosures attic rafters etc Do not pack air spaces with insulation Also note maximum vertical rise of the venting...

Page 13: ...y using a level Temporarily tack the support box in place through the inside walls and into the roof sheathing 4 Using tin snips cut the supportbox from the top corners down to the roofline and fold t...

Page 14: ...VENTING INSTALLATION Continued Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 20 max Figure 27 Vertical Rigid Venti...

Page 15: ...alvanized Coaxial Pipe 6 pcs D1020 7 x 48 Galvanized Coaxial Pipe 6 pcs D1030 7 Adjustable 7 12 Galvanized Coaxial Pipe 6 pcs D1050 7 x 6 Galvanized Coaxial Pipe 6 pcs D2000 7 x 90 Elbow 6 pcs D2010 7...

Page 16: ...nstall this fireplace as your primary heat source If you have acentralheatingsystem youmay run system s circulating blower while using fireplace This will help circulate the heat through out the house...

Page 17: ...see Figure 33 Route power cord through both plastic bushing s and plug the power cord into a properly grounded 3 prong wall receptacle near the firebox b If your fireplace system installation is rece...

Page 18: ...pt able alternative to test gauge connection Purchase the CSA AGA design certified equipment shutoff valve from your dealer WARNING A qualified ser vice person must connect fire place to gas supply Fo...

Page 19: ...ble gas line provided by installer from equipment shutoff valve to fireplace Route flexible gas supply line through one of the access holes on side of fireplace 3 Attach flexible gas line from gas sup...

Page 20: ...off valve see Fig ure 37 2 Open propane LPsupply tank valve for propane LPfireplace or main gas valve located on or near gas meter for natu ral gas fireplace 3 Make sure control knob of fireplace is i...

Page 21: ...place or heat and air conditioning ducts 5 Gently remove the cover of the ther mostat from the base Grasp the sides of the cover firmly and pull to separate from the base 6 Feed the electrical wires t...

Page 22: ...h terminal wires to a 9 volt alka line battery not included Place bat tery into the battery housing 3 Replace battery cover onto remote con trol unit Figure 45 Installing Alkaline Battery in Hand Held...

Page 23: ...48 4 Slide the left retainer bracket against the left side brick panel Loosely se cure the bracket screw This secures the left side brick panel 5 Install the right brick panel using the same method d...

Page 24: ...4 Place log 4 small round log on the pin on the right side of front log as shown in Figure 53 5 Place log 5 small log onto the front left part of the grate making sure the notches fit over the prongs...

Page 25: ...LO The burners will turn on and off automatically to maintain the comfort level you select The ideal comfort setting will vary by household depending upon the amount of space to be heated the output...

Page 26: ...ntrolled blower have an ON setting and an OFF setting The blower will only run when the switch is in the ON position In the OFF position the blower will not operate Note for DA3610TA Only If you are u...

Page 27: ...e To Turn Off Gas to Appliance page 25 see Troubleshooting pages 29 through 31 Figure 59 Pilot Assembly Figure 60 Typical Flame Pattern for models BHDV34NB and BHDV34PB Thermocouple Thermopile 3 8 to...

Page 28: ...gidity WARNING Turn off fireplace and let cool before cleaning CAUTION Youmustkeepcon trol areas burners and circulat ing air passageways of fireplace clean Inspect these areas of fire place before ea...

Page 29: ...oose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holdi...

Page 30: ...e burner until air is removed from line Have gas line checked by local pro pane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 28 or replace burner orifice 1 Adjust the log...

Page 31: ...t blocked 3 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces unwanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odor during combustion Dark...

Page 32: ...o disconnection when servicing controls Wiringerrorscancause improper and dangerous opera tion Verify proper operation af ter servicing Note Use only original replacement parts Thiswillprotectyourwarr...

Page 33: ...ure 4 5 w c 11 0 w c Thermal Efficiency 70 70 Dimension Inches mm HxWxD Fireplace Actual size of firebox Measurements do not 32 3 16 x 34 3 8 x 18 1 2 32 3 16 x 34 3 8 x 18 1 2 include nailing flanges...

Page 34: ...Oak G3004W Series Off White Paint Thehearthbasecreatesahandsomeriserfor the fireplace cannot be used with corner mantel Dimensions WxHxD 58 x61 2 x289 16 CORNER MANTEL GM200F Series Walnut Stained Har...

Page 35: ...es installation and removal quick and easy They are designed to go at the top and bottom of the glass door on BHDV units Note Remove the plastic film covering on strips before installing on fireplace...

Page 36: ...ND BHDV34PB ILLUSTRATED PARTS BREAKDOWN BHDV34NB BHDV34PB 48 31 3 1 2 3 4 6 6 36 5 5 6 5 11 Included in Hardware Pack 7 7 8 10 9 12 13 14 15 16 17 18 19 20 32 21 22 23 24 25 26 27 28 28 29 30 33 32 32...

Page 37: ...P 1 19 104498 01 Thermocouple 1 20 104499 01 Thermopile 1 21 104500 01 Ignitor 1 22 104501 01 Ignitor Bracket 1 23 104502 01 Ignitor Screw 1 24 104503 01 Ignitor Wire 1 25 104504 01 Burner Natural 1 1...

Page 38: ...airing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL OTHER EXPRESS...

Reviews: