![Vanguard Instruments Company SGT-600 User Manual Download Page 7](http://html1.mh-extra.com/html/vanguard-instruments-company/sgt-600/sgt-600_user-manual_3385505007.webp)
http://www.51082245.com
SGT-600 USER’S MANUAL
REV 1
4
1.2
SGT-600 Technical Specifications
TYPE
Portable Micro-Ohmmeter
PHYSICAL SPECIFICATIONS
Dimensions:
16.75”W x 12.5”H x 12” D (42.7 cm x 32 cm x 30.5 cm)
Weight:
19.8 lbs. (8.9 Kg)
INPUT POWER
100 ̶ 240 Vac, 50/60 Hz
RESISTANCE READING
RANGE
1 micro-ohm to 1000 milliohms
(max 1.5 milliohms @ 600A, 450 milliohms @ 10A, 1000 milliohms @ 1A)
TEST CURRENT RANGE
10A ̶ 600A (selectable in 1A steps);
thermally protected DC power supply
ACCURACY
10A ̶ 49.9A: 1% ±2 micro-ohms, 50A ̶ 600A: 1% ±1 micro-ohm
TEST VOLTAGE
5 Vdc
DISPLAY
back-lit LCD screen (128 x 64 pixels)
viewable in bright sunlight and low-light levels
KEYPAD
rugged, 44-key "QWERTY"-style membrane keypad
INTERNAL
TEST RECORD STORAGE
100 test records
EXTERNAL
TEST RECORD STORAGE
up to 999 test records on external USB flash drive
PC SOFTWARE
Windows®-based analysis software is included with purchase price
COMPUTER INTERFACES
one RS-232C PC interface, one USB flash drive interface
PRINTER
built-in 2.5” wide thermal printer
SAFETY
designed to meet IEC 61010 (1995), UL 61010-a, and CAS-C22.2 standards
TEMPERATURE
Operating:
-10°C to +50°C (+15°F to +122°F)
Storage:
-30°C to +70°C (-22°F to +158°F)
HUMIDITY
90% RH @ 40°C (104°F) non-condensing
ALTITUDE
2,000 m (6,562 ft) to full safety specifications
CONNECTION POSTS
Two 2”/3” diameter posts
CABLES
sensing leads, hand probes, power cord, ground cable
OPTIONS
shipping case
WARRANTY
one year on parts and labor
NOTE
The above specifications are valid at nominal operating voltage and at a
temperature of 25
°
C (77
°
F). Specifications may change without prior notice.