background image

4K 8x6 HDBaseT™ 

Matrix Switcher with 

2 HDMI Outputs, IR, 

IP and RS-232

Part Number:

EVMX8X6

 

www.vanco1.com • 800.626.6445 

 

4K HDBaseT

 8x6 

 

M   A T     R    I    X 

     

   

with 2 HDMI Outputs, IR, IP and RS-232 

Summary of Contents for Evolution EVMX8X6

Page 1: ...4K 8x6 HDBaseT Matrix Switcher with 2 HDMI Outputs IR IP and RS 232 Part Number EVMX8X6 www vanco1 com 800 626 6445 4K HDBaseT 8x6 MA TRIX with 2 HDMI Outputs IR IP and RS 232 ...

Page 2: ...cularly at the plugs 9 Use unit only with accessories specified by the manufacturer 10 Refer all servicing to qualified personnel CAUTION HDMI is a very complex technology requiring continuous authentication of the signal and the same video resolution and audio settings on all electronic equipment in the system When there are multiple sources and displays the video resolution and audio setting on ...

Page 3: ...at choice for any application FEATURES 4K 8x6 HDBaseT Matrix Switcher with 2 HDMI Outputs IR IP and RS 232 Part EVMX8X6 4K 8x6 HDBaseT Matrix that accommodates 6 HDBaseT outputs and 2 HDMI outputs Extends 4K 60Hz 4 4 4 and HDR10 up to 131ft 40m over a single Cat6 cable Outputs 4K 60Hz 4 4 4 HDR10 and Dolby Vision on the HDMI inputs and outputs Extends 1080p resolution up to 230ft 70m over a single...

Page 4: ... Dolby Atmos Dolby TrueHD Dolby Digital Plus DTS X and DTS HD Master Audio pass through Audio Output 2 SPDIF 2 RCA L R Audio Output Connector 2 Toslink connectors 4 3 5mm jacks Digital SPDIF Audio Format Supports PCM Dolby Digital DTS DTS HD Analog RCA L R Audio Format Supports PCM Frequency Response 20Hz 20KHz 3dB Audio Output Impedance 70 Ohms Max Input Level RCA 2 0Vrms 0 5dB 2V 16dB headroom a...

Page 5: ...Stereo Channel Separation 70dB 1KHz Noise Level RCA 80dB SPDIF 90dB Control Port 1 FW 6 IR IN 1 IR ALL IN 8 IR OUT 1 IR ALL OUT 1 IR EYE 1 RS 232 1 TCP IP Control Connector 1 Type A USB 17 3 5mm jacks 1 3 pin terminal block 1 RJ45 Transmission Mode HDBaseT Transmission Distance 1080p 230 feet 70 meters 4K 60Hz 131 feet 40 meters I Bandwidth 18 Gbps Operation Temperature 5 to 55 23 to 131 F Storage...

Page 6: ...selected 4 Menu Buttons ENTER Switches input s to output s after input output selection LOCK Locks Unlocks front panel buttons ALL Selects all inputs and or outputs for switching CLEAR Cancel 5 PRESET RECALL There are up to 4 presets which can be saved for easy switching to any source display configuration Press and hold any preset button 1 4 to save the current switching status this saves the cur...

Page 7: ...this if you would like to control the display s over HDBaseT receiver s have IR outputs ALL IN Connect the included IR Receiver RX to this port this will send an IR signal out to all HDBaseT receiver s useful feature to turn on off all displays at one time 5 AUDIO OUTPUTS Digital optical outputs and analog RCA outputs for HDMI outputs 7 and 8 6 CONTROL TCP IP Connect to a local network such as a r...

Page 8: ...ption of either the EVRXHD2 or EVRXDSC connect HDMI cables from the receivers to each HDMI display NOTE HDMI certified cables are strongly recommended for 4K HDR resolution 4 Connect an HDMI display to output 7 and 8 NOTE HDMI certified cables are strongly recommended for 4K HDR resolution 5 OPTIONAL Connect an external amplifier or AV Receiver to the digital and or analog output NOTE both the dig...

Page 9: ...e input output button the buttons will go off after eight seconds 5 1 Signal Switching S Source D Display Switch an input to an output Operation INPUT OUTPUT ENTER Example Switch Input 1 to Output 2 Switch an input to multiple outputs Operation INPUT OUTPUT OUTPUT ENTER Example Switch Input 1 to Output 2 3 and 4 Press Press Switch an input to all outputs split one source to all displays Operation ...

Page 10: ... manually switch each input output Press and hold the PRESET 1 4 for 3 seconds to save the current switching status to the corresponding preset 1 4 Press the PRESET 1 4 o recall the saved preset 1 4 Note The front panel only holds 4 presets however the UI via IP control gives the ability of saving up to 9 presets 5 5 CLEAR Button cancel Press the CLEAR button to cancel USER INTERFACE CONTROL The m...

Page 11: ... to record the password s The UI is available in two formats one as a master for the integrator and or admin and another for end users that restricts access to only switching inputs outputs Username Password Access Rights admin Set on welcome page or Access tab All tabs user Set on Access tab to activate user account Only on switching tab ...

Page 12: ...he button on the Input 1 row and Output 1 column directs input 1 to output 1 Use the 9 numbered buttons under scene area to save and load layout presets To save a given layout first click one of the numbered buttons then click the Save button To load a previously saved layout first click one of the numbered buttons then click the Recall button ...

Page 13: ... 6 2 1 PoC Setting you can disable the Power over Cable setting on the EVRXHD2 or EVRXDSC receivers Turn on or off PoC for 1 HDBT 6 HDBT output 6 2 2 EDID Copy Copy the EDID of the selected output device to one or more input source devices ...

Page 14: ...ut sources Upload user defined EDID by the below steps 1 Prepare the EDID file bin on the control PC 2 Select the User defined 3 Click the box and then select the EDID file bin according the tooltip 4 Click Apply to upload the user defined EDID and then click Confirm to save setting 6 3 RS 232 Tab 1 Local ...

Page 15: ...2 pass through settings on the EVRXHD2 and EVRXDSC receivers HDBT The RS 232 port of the HDBaseT receiver Port Select one of HDBT outputs which are connected to the HDBaseT receivers which must have third party device connected Baud Rate Supports 2400 4800 9600 19200 38400 57600 or 115200 Command Ending NULL CR LF or CR LF can be chosen Command Typing the commands in the box to control the selecte...

Page 16: ...enamed to make it easier when switching sources to displays Simply type in the new name for each input output then click Confirm 6 5 Network Tab Adjust to Static IP or Dynamic Host Configuration Protocol DHCP Modify the static IP Address Subnet Mask and Gateway ...

Page 17: ...send input 1 to outputs 1 and 4 first press the INPUTS 1 button then press both the OUTPUTS 1 and 4 buttons and finally press the ENTER button to execute the change To send input 4 to all outputs first press the INPUTS 4 button then press the ALL button and finally press the ENTER button to execute the change To set the EDID for one or more source devices to the EDID capabilities of a specific out...

Page 18: ...al input device through IR OUT port Example Switch HDMI input 2 to HDBaseT output 3 Connect an IR receiver to IR IN port on the receiver then connect an IR emitter to the IR OUT 2 on the matrix switcher The third input source can be controlled through its corresponding IR output port The connection diagram shown as below Control local input device through IR ALL OUT port The emitter can be connect...

Page 19: ...Connect an IR receiver to IR IN 3 port on the matrix switcher then connect an IR emitter to the IR OUT on the receiver as shown in the diagram below Control remote device through IR ALL IN port The receiver can be connected to the IR ALL IN port on matrix switcher to control all remote output devices In this case the IR emitter must be connected to the IR OUT port on each connected HDBaseT receive...

Page 20: ...witcher from Local 7 2 3 Integration with 3rd Party Control The EV IRMST IR integration cable is included with the matrix unit Seamlessly integrate IR from the EVMX8X6 with third party control systems and other IR products to provide a cleaner faster installation Eliminates the need to cut and splice wires or tape emitters and receivers together Simply plug the red connector into the EVMX8X6 and t...

Page 21: ...control mode for all HDBaseT outputs and send the command RS232RCM0OFF to disable the remote control mode for all HDBaseT outputs Please refer to the 8 3 1 System Control for more details To control a remote third party device from local first determine which HDBaseT receiver is connected to 1 in the diagram below Next connect a PC to the corresponding RS 232 port of matrix switcher with 3 pin to ...

Page 22: ...e g projector to the RS 232 port of matrix switcher The local third party device can be controlled by the remote PC the connection diagram is shown as below 8 1 4 Control the Local Third party Device from Remote When controlling the switcher the serial port settings for all RS 232 commands is Baud rate 9600 Data bit 8 Stop bit 1 Parity bit none Please visit the product page at www vanco1 com for a...

Page 23: ...ical Support by dialing 1 800 626 6445 You can also email technical support issues to techsupport vanco1 com When calling please have the Model Number Serial Number affixed to the bottom of the unit and Invoice available for reference during the call Please read this Instruction Manual prior to calling or installing this unit since it will familiarize you with the capabilities of this product and ...

Page 24: ...Vanco International 506 Kingsland Drive Batavia Illinois 60510 call 800 626 6445 fax 630 879 9189 visit www vanco1 com ...

Reviews: