10. Specifications
Specifications are subject to change without prior notice.
Article number
V54538-F124-A100
Short Description
WPIR-EXT AM Wrls. Ext PIR c/w pet
Detection Method
Double PIR Elements with optional Anti-masking feature
WA Detection Pattern
90⁰ with 30 zones detection
Data Protocol
Freewave2 Two Way Protocol with unique serial ID
Modulation Type
GFSK
Frequency
868-869MHz
Events Transmission
Alarm, Anti-Mask, Tamper, Supervision, Low Battery
Supervision Time
7 min by default (configurable between 1 to 30 minutes)
Detection Range
Configurable from 3m to 12m
Installation Height
From 0.8m to 1.5m (Optimal 1.2m)
Range in open space
500m
Battery
4 Lithium Batteries 1,5V Type AA LR06
Battery life
Up to 5 years
Current Consumptions
Standby ~22 A
Receive mode ~24 mA
Transmit mode ~45 mA
Transmit Power: ~14dBm
Tamper Switch
Front Cover and Wall Removal (Back Tamper)
Weatherproofing
All openings with gasket and sealed.
Protection against water and dust
RFI Protection
10V/m plus 80% AM from 80MHz to 2GHz
EMI Protection
6kV contact, 8kV air
Tamper Switch
Front Cover and Wall Removal (Back Tamper)
Temperature Compensation
Yes, Dual slop temperature compensation
Alarm Period
2 sec (±0.5sec)
Warm up Period
30 sec (± 5sec)
LED Indicator
LED is ON during ALARM and TROUBLE
Operation Temp
-25ºC ~ +55ºC
Protection Degree
IP 65
Dimensions
200mm x 86mm x 80mm
Weight (Nett)
0.640 Kg